12
11
RD04
24V
F
RD21
9,5V L
E
X2:11
X2:1
RD21
RD04
RD15
D
X1:1
X1:4
X6:1
9,5V L
24V L
24V AC
FUSES
FUSES
F1
F2 + F3
IMAX =
IMAX =
1,6 AT
3.15 AT
9,5V N
24V N
12V M
N24V AC
C
X1:2
X1:5
X1:6
X6:4/9/10
RD22
RD01
RD26
RD09
X2:12
X2:2
X2:10
9,5V N
RD22
X2:7
X1:9
24V N
B
RD01
12V M
RD26
A
12
11
10
9
8
21
S1
EMERGENCY STOP
22
X2:5
RD07
14
S1
S2
M1
96
13
FT1
22
S2
95
RD106
21
X2:6
X2:4
RD08
RD105
RD106
BU05
X6:3
X6:2
X8:1
X8:2
I 24V AC
II 24V AC
AC IN
EMERG.
SIGN. OVERLOAD
VT3
VT4
TRIAC
TRIAC
GATE
GATE
X6:5
X6:8
RD11
RD12
X3:6
X3:7
A2
A2
K1
K2
A1
A1
10
9
8
7
6
BU101
12
:98
FT1
11
:97
WIRE STRAP:
CODE SIGN FOR
"EXCICUT
TABLE
CONNECTION"
X3:1
X3:3
X3:2
BU02
BU03
BU101
X8:3
X8:4
X8:5
X8:7
X8:8
X15:1
X8:6
CODE INPUT
SAFETY GUARD
GUARD
RECIR.
SOURCE
LOCK OR
OVERLOAD
GND
RELEASE
RELAY
DC MOTOR
VT1
VT2
TRIAC
TRIAC
GATE
GATE
+24V
+24DC OUTPUT.
X6:6
X6:7
X3:1
RD13
RD14
BU04
X3:9
X3:8
X3:4
BU04
X1:10
A2
A2
BU04
K3
K4
M5:1
A1
A1
+
WH
RD09
Rev.C: (03-01-2005 OH)
- removed YM1, X5
- removed wires BU13, BU14, BU15, BK, BN, VT
- changed: S2:21 to 12, S2:22 to 11, S2:11 to 22, S2:21 to 21
- removed wires BU11 + RD, BU12 + BU
- new wires: X4:3 to S2:A2 <BU112>, X4:1 to S2:A1 <BU111>
- RD6 changed to RD106
- removed X2:3 and wire RD5
- new wire: X6:2 to S2:21 <RD105>
7
6
5
4
WH
YE
X17:1
X17:3
CUTTING
WH
WH
CURRENT
BQ01
BQ02
T2
ITRANS
NAMUR
NAMUR
BK
GR
BK
BK
X1:7
X1:8
X17:2
X17:4
X2:8
X2:9
RD18
RD19
BN
GN
X15:2
X15:3
X10:1
X10:2
X11:2
X12:2
VALVE IN
CUTTING
VALVE IN
SLUCING
CURRENT
COOLING
POSITION.
POSITION.
DRIVER
AKTUATOR
M24V
± 24 V DC.
X3:2
X4:1
X4:3
BU05
BU111
BU112
X3:5
BU05
X1:11
M5
BU05
M5:2
S2
-
A1
A2
BK
SAFETY
Rev. B. Colors on
BQ1 & BQ2 changed
Tuesday, January 03, 2006
5
4
3
2
1
BN
X18:2
X13:7
BK2
BK
X19:1
BU
RP1
BS03
PD300
NAMUR
BN
WH
YE
X19:1
BK1
X18:1
X13:5
X13:6
WH
BN
WH
YE
BK
WH/YE
X11:1/12:1
X9:1
X9:2
X14:1
X14:2
X14:3
X-TABEL
ARM POS
REFF. POS.
ADD INPUT:
DRIVER
DRIVER
STEPMOTOR
STEPMOTOR
X2:1
X2:2
X2:3
X2:4
X5:1
X5:2
X5:3
X5:4
WH
BN
GN
YE
WH
BN
GN
YE
X18:6
X18:5
X18:4
X18:3
BK6
BK5
BK4
BK3
X19:6
X19:5
X19:4
X19:3
X13:1
X13:2
X13:4
X13:3
GN
RD/WH
GN
RD/WH
GN/WH
RD
GN/WH
RD
STEPMOTOR
STEPMOTOR
Struers A/S
Valhoejs Alle 176
DK 2610 Roedovre
Denmark
Phone +45 3670 3500
Control Circuit Diagram
Unitom - 50:
With Excicut Table.
Size
CAGE Code
DWG NO
15313120
A2
EK
Scale
Sheet
08.03.99 / DEM
D.E.M.
1
of
3
2
1
F
E
D
C
B
A
Rev
C
1

Publicité

Table des Matières
loading

Table des Matières