Power Requirements
Jacuzzi spas are designed to provide optimum performance
and flexibility of use when connected to the maximum electrical
service listed below. Minor circuit board modifications can be
performed to allow your new spa to accept an electrical service
other than the factory operation setting.
Terminal
Ampere
Breaker N°
1
16 A
32 A
2
(a)
(b)
J-315
(a)
(b)
J-325
(a)
(b)
J-335
(a)
(b)
J-345
(a)
(b)
J-355
(a)
(b)
J-365
(a)
(b)
J-375
(a)
(b)
J-385
Volt 220-230 V ~ Hertz 50
(*) This is the factory setting.
This operation can only be performed by authorized Jacuz-
zi® technicians and limits electricity consumption as follows:
(a)
The heater will not operate while either jets pump is run-
ning.
(b) The heater will operate while two jets pump are running.
(c) The heater will operate while both jets pump are running.
This is the factory setting.
See "Dip Switch Settings" chapter.
Electrical Wiring Instructions
To gain access to the spa's power terminal block, press the rele-
ase button securing the cabinet panel under the control panel.
Refer to Section "Draining and Refilling" for instructions on how
to remove the cabinet panel(s). Then remove the six door screws
on the control box. Place the panel is a safe location to prevent
damage.
Select the power supply entrance you want to use. Make sure
to install a 3/4" electrical fitting and conduit through the large
opening provided in the bottom of the control box so you can
feed the cable through to the terminal block.
Connect wires to the terminal block. ALL WIRES MUST BE SECU-
RELY CONNECTED or equipment damage could result!
9
12
8
10
1
3
11
4
16 A
16 A
(c)*
(c)*
(c)*
(c)*
(c)*
(c)*
(c)*
(c)*
1
Electrical box
2
Power supply entrance(s)
3
1 Speed Pump (pump 1)
4
Heater
5
Drain valve
6
Pump drain plug(s)
7
1-Speed pump
2
8
Circulation pump
5
9
Control Panel
6
10 CLEARRAY™ (Ultraviolet) Water Purification System
11 Electronic Ballast (for the CLEARRAY™ System)
12 Optional ProLink™ Monitoring System
Install control access box door and reinstall the cabinet panel(s).
TB3
Vert
Start-up instructions
Read each step in its entirety before proceeding with that
step.
Remove any dirt from the spa. Although the spa shell has
been polished at the factory, you may want to treat it with a spe-
cially formulated spa cleaner and wax available from your dealer
prior to filling the first time.
Filling the spa
Remove the filter cover, then remove both filter cartridges as
outlined in section "Cleaning The Filters".
Position the end of the hose inside the filter connection and fill
the spa until the level of water covers all of the nozzles, without
however reaching the headrest.
Do not overfill your spa.
N.B.: If your water is extremely hard, it is preferable to fill halfway
with hard water and the rest of the way with softened water.
Always refill the spa through both filter fittings to purge trapped
air from pump intakes. Failure to do so may cause air to be trap-
ped in either pump 1 or the circulation pump's intake, preven-
ting the pumps from circulating water.
After filling, make sure both filters are installed properly before
applying power to the spa. (refer to sec.) "Cleaning the filters").
26
STEP LIGHT
(OPTIONAL)
J59
J51
J41
J47
J38
J33
J36
J46
J53
TB3
F3 0.125A 240V
TB1
Monophasée
Blu
Brn
J41
J47
J38
J33
J36
J46
J53
TB3
TB1
Vert
Biphasée 2
Monophasée
J41
J47
J38
Brn Blu BrnBlu
J33
J36
J46
J53
TB1