2ND STEP: CONNECT THE SOLAR MODULE
-
Ensure that the solar module is protected from incident light
(cover it or wait for night).
-
Ensure that the solar module does not exceed the maximum
permissible input current.
-
First connect the M+ solar module connection cable to the correct
pole of the left pair of terminals on the solar charge controller
(with the solar module symbol), then connect the M– cable. Remove
the covering from the solar module.
3RD STEP: CONNECT LOADS
-
First connect the L+ load cable to the correct pole of the right pair
of terminals on the solar charge controller (with the lamp symbol),
then connect the L– cable. Insert the load fuse or switch on the load.
Notes: Connect loads that must not be deactivated by the solar
charge controller deep discharge protection, e.g. emergency lights or
radio connection, directly to the battery. Loads with a higher current
consumption than the device output can be directly connected to the
battery. However, the solar charge controller deep discharge protection
will no longer intervene. Loads connected in this manner must also be
separately fused.
4TH STEP: FINAL WORK
Fasten all cables with strain relief in the direct vicinity of the solar charge
controller (clearance of approx. 10 cm).
5. LED DISPLAYS
LED
Illuminates GREEN
Flashes slowly RED*
INFO LED
Flashes quickly*
Battery
RED LED
Flashes slowly*
Illuminates
Battery
Flashes slowly
YELLOW
YELLOW*
LED
Illuminates
Battery
GREEN
Flashes quickly
LED
GREEN*
STATUS
MEANING
Normal operation.
System Fault: too high charging
current; overload/short circuit;
overheated.
TOGETHER WITH RED LED:
too low battery voltage.
TOGETHER WITH GREEN LED:
too high battery voltage.
Battery empty, low voltage
disconnection pre-warning,
loads still ON.
Deep discharge protection active
(LVD), loads disconnected.
Battery weak, loads are ON.
LVD reconnection set-point has
not yet been reached, loads still
disconnected.
Battery good.
Battery full, charge regulation active