A
B
A
B
C
A
B
2
NVM/300
C
NVM/300
D
E
NVM/300
C
D
NC/321 in series 300 video entry con-
trol installations.
It can be inserted, combined with the
hands-free module in a standardised
double embedding box, or on its own
in a standardised rectangular single
embedding box.
The unit comes with a chassis and
adapters for the use of a number of
commercially available front plate
models.
It features the following controls (fig. 1):
Brightness
Saturation colour
Entry panel activation
•
Centralized control (stairs light
and entry panel selection)
Function of each terminal (fig. 2)
Terminal block M1
12÷16 V AC, 14÷18 V DC
monitor supply voltage
Function of jumper SW1
6
Normally supplied with jumper insert-
ed (ON) to apply resistive load termi-
nation on the line (fig. 2).
Remove the jumper if the line continues.
Function of connector CN1
Connect monitor module to audio
module with the relevant cable sup-
plied (fig. 2).
Technical features
• Video signal system: PAL.
• Display: 2" colour LCD Poly-Silicon
TFT.
• Resolution: 557x234 dots.
• Supply voltage: 12÷16 V AC,
14÷18 V DC.
• Current demand: max. 220 mA (5
mA in stand-by).
• Working temperature range: from 0
°C to +35 °C.
Installation
The monitor module can be installed
teamed with twin-channel module
NC/321 in an embedding box (fig. 4),
or on its own teamed with the twin-
channel module (fig. 3).
In the latter case, the distance
between the modules will depend on
7
the length (24 cm) of the cable sup-
plied.
Recess the embedding box flush with
the wall at a suitable height for the
user.
WARNING. To remove the monitor
module from the chassis, lift the
locking clips and push from the rear
(fig. 5).
Examples
of
assembly
NVM/300 monitor module in a stan-
dardised single embedding box with a
number of commercially available
front plates:
1 (fig. 6)
A (embedding box)
B (BPT chassis)
C (BTICINO Living series art. L4803
or Light series art. N4803 front
plate).
2 (fig. 7)
A (embedding box)
B (BPT adapter for VIMAR front
plate)
C (BPT chassis)
8
D (BPT hole plug adapter)
E (VIMAR Idea or Rondò series front
plate).
3 (fig. 8)
A (embedding box)
B (BPT chassis)
C (BPT hole plug adapter without
connecting rods)
D (GEWISS Playbus series front
plate).
Examples
of
assembly
NVM/300 monitor module in a stan-
dardised double embedding box com-
bined with the hands-free module
NC/321, with a number of commer-
cially available front plates:
4 (fig. 9)
A (embedding box)
B (BPT chassis) (kit NS/6)
C (11 mm BPT hole plug adapters)
(kit NS/6)
D (BTICINO Living series art. L4807
or Light series art. N4807 front
plate).
5 (fig. 9)
A (embedding box)
B (BPT chassis) (kit NS/6)
C (9 mm BPT hole plug adapters) (kit
NS/6)
D (VIMAR Idea or Rondò series front
plate, GEWISS Playbus series front
plate, AVE System 45 series front
plate).
WARNING. When using BTICINO
(Living or Light series) front plates
and GEWISS (Playbus series) front
plates, the fastenings indicated in fig.
10 must be removed. Instead, when
using VIMAR (Idea or Rondò series)
front plates, the fastenings indicated
in fig. 11 must be removed.
INSTALLATIONS-
D
ANLEITUNG
FARBMONITORMODUL
NVM/300
Der Farbmonitormodul ist in den
Videosprechanlagen
zusammen mit dem Modul mit
Freisprechfunktion NC/321 zu benut-
zen.
Kann zusammen mit dem Freisprech-
modul in einen genormten Doppel-
tenkasten für die Unterputzmontage
eingefügt werden.
Oder kann alleine in einem rechtecki-
gen Dreimodulkasten für die Unter-
putzmontage eingefügt werden.
Das Gerät ist mit einem Rahmen und
of
the
Adaptern für die Benutzung ver-
schiedener
handelsüblichen
bleaumodelle ausgestattet.
Ist mit den folgenden Steuerfunktio-
nen ausgestattet (Abb. 1):
Helligkeit
Farb-Saturation
Außenstationeneinschaltung
•
Zentralsteuerung (Treppenlicht,
Kamerawahltaste)
Funktion der Klemmleisten (Abb. 2)
Klemmleiste M1
12÷16 V AC, 14÷18 V DC
Monitormodulversorgung
of
the
Serie
300
Ta-