Carl Zeiss
Legend to Fig. 14:
1 Eyepieces
2 Binocular body of the tube
3 Tube
4 Carrying handle
5 Plug-in power unit
6 Illumination-intensity indicators
7 Rotary knob for switching ON / OFF and adjusting the illumination intensity
8 Fine focusing drive (right side)
9 Coarse focusing drive (right side)
10 Control knob for X travel of mechanical stage
11 Control knob for Y travel of mechanical stage
12 Clamping screw for condenser
13 Transmitted-light illuminator, LED or HAL
14a Knurled ring for adjusting the luminous-field diaphragm (with Full-Köhler equipment only)
14b Luminous-field diaphragm (fixed in Fixed-Köhler equipment)
15a Centering screws for condenser on condenser carrier (in Full-Köhler equipment: knurled screws)
15b Centering screws for condenser on condenser carrier (in Fixed-Köhler equipment: Allen screws)
16a Abbe condenser, Full-Köhler
16b Abbe condenser, Fixed-Köhler
17 Objective
18 Microscope stage
19 Spring lever of specimen holder
20 Knurled ring of objective nosepiece
21 Lever for adjusting the aperture diaphragm of the condenser
22 Knurled knob for vertical adjustment of condenser
23 Coarse focusing drive (left side)
24 Fine focusing drive (left side)
25 Knurled ring for adjusting the smoothness of the coarse focusing drive
Legend to Fig. 15:
1 Special eyecups with light protection
2 Eyepieces
3 Binocular body of the tube
4 Tube
5 Transmitted light / reflected light changeover switch (Brightfield / Fluorescence)
6 Rotary knob for switching ON / OFF and adjusting the illumination intensity for reflected light
7 Carrying handle
8 Plug-in power unit
9 Illumination-intensity indicators for transmitted light
10 Rotary knob for switching ON / OFF and adjusting the illumination intensity for transmitted light
11 Fine focusing drive (right side)
12 Coarse focusing drive (right side)
13 Control knob for X travel of mechanical stage
14 Control knob for Y travel of mechanical stage
15 Clamping screw for condenser
16 Transmitted-light illuminator LED
17 Yellow filter (with filter position for adapting the color temperature in transmitted light and with position for blocking the
transmitted-light path in case of reflected-light fluorescence applications)
18 Luminous-field diaphragm (fixed)
19 Centering screws for condenser on condenser carrier
20 Abbe condenser, Fixed-Köhler
21 Objective
22 Microscope stage
23 Spring lever of specimen holder
24 Knurled ring of objective nosepiece
25 Pilot lamp for reflected-light fluorescence illuminator: lighting blue when switched on; brightness corresponds to intensity
26 Lever for adjusting the aperture diaphragm of the condenser
27 Knurled knob for vertical adjustment of condenser
28 Coarse focusing drive (left side)
29 Fine focusing drive (left side)
30 Knurled ring for adjusting the smoothness of the coarse focusing drive