Probable cause #4:
Individually adjustable volume jets are adjusted to low volume.
Action:
Turn face of specific jet to increase water volume.
Probable cause #5:
Air control is closed. No visible air/water mix.
Action:
Open air control to increase air/water mix.
Probable cause #6:
Pump has overheated and tripped internal thermal overload.
Action:
Wait for pump to cool & listen for "snap" sound as overload resets. Pump should restart.
Contact dealer if problem persists.
Probable cause #7:
Pump is not pumping due to broken part inside (motor works, pump is primed but there
is no water movement from pump).
Action:
Contact dealer for service.
Air Injectors Do Not Bubble When Blower Key is Pressed
Probable cause #1:
Air blower is not plugged in to spa pack.
Action:
Plug blower in and test
Probable cause #2:
Blower fuse blown in spa pack.
Action:
Locate and test/replace blower fuse in spa pack. Call dealer if problem persists.
Probable cause #3:
Air blower disconnected from blower plumbing.
Action:
View blower plumbing and reconnect if disconnected. Test.
Probable cause #4:
Air blower has overheated and thermal overload has tripped.
Action:
Wait for blower to cool and reset. Re-test. Call dealer if problem persists.
LED Light(s) Do Not Come On When Light Key is Pressed
Probable cause #1:
Light fuse blown in spa pack
Action:
Locate and test/replace light fuse in spa pack Call dealer if problem persists.
Probable cause #2:
In -line or on board fuse blown in LED controller
Action:
Locate and test/replace light fuse in LED control box.