5- Electrical wiring

5.1 Electric cable selection
Lewmar recommends the installer source and install cable that meets the requirements of the
standards and regulations relevant to the installation and codes of practice.
The cable table gives recommended cable sizes based on total length of cable required, from the
battery, following the route of the cables.
CABLE SIZING FOR LENGTH OF CABLE RUN
up to 14 m up to 40 ft
6 mm²
10 AWG
Windlass performance is directly related to cable size and length. Voltage drop over the complete
wiring run must not exceed 10%.
5.2 Wiring
Plan the installation to suit the controls and give the operator a full view of the windlass. The wiring
system should be of the fully insulated type, which avoids possible electrolytic corrosion problems.
We recommend the use of type III stranded, tinned copper wire with copper crimp terminals. Most
modern installations are negative return (negative ground) but polarity should be checked.
Overload protection, in the form of the circuit breaker provided must be built into the windlass wiring
circuit.
• Circuit breaker supplied:
Pro-Serie/Fish 700 - 50A (Part No 68000348)
Pro-Serie/Fish 1000 and Pro-Fish Pb - 70A (Part No 68000240)
• The circuit breaker should be positioned close to the battery in a dry, readily accessible place.
• The breaker must be manually reset should an overload occur that causes it to trip to the off
position.
WARNING!
• If you are not sure you understand these guidelines, seek professional help. Ensure that the
installation complies with USCG, ABYC, NMMA or other local regulations.
5.3 Control switch installation
The unit is supplied with
• Guarded rocker switch (product ref 68000593)
• Contactor (product ref 68000939)
Follow the wiring diagram § 5.4
NOTE: Optional electric footswitches and remote handheld control available.
Visit www.lewmar.com for more information
Contactor box and control box used in some installation refer to wiring diagram
§ 5.5 and § 5.6
Optional wireless remote also available
See table below for models and references
WIRELESS REMOTE
(3 button windlass only)
68000967
NOTE: In a multi station installation all switches must be wired in a parallel circuit.
6
15 - 24 m
41 - 66 ft
10 mm²
8 AWG
WIRELESS REMOTE
(5 button windlass & thruster)
68000968
DO NOT confuse cable length
with the length of the vessel