12. Technical specifications of the detectors
Maximum protected distance for
interior use
Maximum protected distance for
outdoor use with thermostat-
controlled heating
Type of detection
Number of beams
Detection mode
Intruder alarm response time
Interruption alarm response time
Typical duration of intruder alarm
Power supply
Current consumption at 12 VDC:
• Complete detector
• Receiver alone
• Transmitter alone
Heating power supply
Current consumption of heating
alone at 12 VDC:
• Complete detector
• Receiver alone
• Transmitter alone
NC contact tamper detection
output in addition to alarm
NC contact intruder detection
output in addition to alarm
NC contact interruption detection
output in addition to alarm
Capacity of intruder alarm relay
contact
Capacity of interruption alarm
relay contact
Capacity of tamper alarm relay
contact
Operating temperature for
version with
thermostat-controlled heating
Protection rating
Weight
Electromagnetic compliance
Cell direction adjustability
Module direction adjustability
Built-in alignment features
SB250
SB2100
125 m
250 m
50 m
100 m
Pulsed infrared beam of wavelength 950 nm at a choice of 4
frequencies (channels).
2 beams
Both beams interrupted
Adjustable from 50 ms to 600 ms
Max. 60 seconds, non-adjustable
Duration of beam interruption, with a minimum of 4 seconds
55 mA
55 mA
35 mA
35 mA
20 mA
20 mA
170 mA
170 mA
85 mA
85 mA
85 mA
85 mA
yes (cutting the intruder alarm)
0.8 kg
0.9 kg
Complies with European standards (СЄ label)
Optical viewfinder system, outputs for measuring the received signal.
16
SB450
SB4100
125 m
50 m
4 beams
All 4 beams interrupted
10 V to 15 VDC
65 mA
40 mA
25 mA
10 V to 15 VAC/VDC
340 mA
170 mA
170 mA
yes
yes
30 VDC – 500 mA
30 VDC – 500 mA
30 VDC – 50 mA
-25°C to +55°C
IP44
1.1 kg
Vertically by +/- 10°
Horizontally by +/- 90°
SB4200
250 m
350 m
100 m
200 m
65 mA
65 mA
40 mA
40 mA
25 mA
25 mA
340 mA
340 mA
170 mA
170 mA
170 mA
170 mA
1.2 kg
1.2 kg