section 4. operation

4.1

start-up

CaUTion
Never run the pump without water. Running the pump
"dry" for any length of time can cause severe damage
to both the pump and motor and will void the warranty.
If this is a new pool installation, make sure all piping
is clear of construction debris and has been properly
pressure tested. The filter should be checked for proper
installation, verifying that all connections and clamps are
secure according to the manufacturer's recommendations.
Warning
To avoid risk of property damage, severe personal
injury or death, verify that all power is turned off before
starting this procedure.
1.
Release all pressure from the system and open
the filter pressure release valve.
2.
Depending on the location of the pump, do one
of the following:
- If the pump is located below the water level of
the pool, open the filter pressure release valve to
prime the pump with water.
- If the pump is located above the water level of
the pool, remove the lid and fill the basket with
water before starting the pump.
3.
Prior to replacing the lid, check for debris around
the lid o-ring seat. Debris around the lid o-ring
seat will cause air to leak into the system and will
make it difficult to prime the pump.
4.
Hand-tighten the lid to make an air tight seal. Do
not use any tools to tighten the lid: hand-tighten
only. Make sure all valves are open and the
unions are tight.
5.
Restore power to the pump. Then turn on the
pump by following the instructions in the
appropriate manual: Variable-Speed Controller
Owner's manual, H0311200, AquaLink
Owner's Manual, 6593, or AquaLink PDA
Owner's Manual, H0572300.
6.
Once all the air has left the filter, close the
pressure release valve.
7.
The pump should prime. The time it takes to
prime will depend on the elevation and length of
pipe used on the suction supply pipe. See Section
3.1.3.3, Installation Recommendations, for
proper elevation and pipe size.
|
Variable-Speed Pump
Installation & Operation Manual
RS
®
8.
If the pump does not prime and all the
instructions to this point have been followed,
check for a suction leak. If there is no leak, repeat
Steps 2 through 7.
9.
For technical assistance, call Zodiac Technical
Support at 800.822.7933. In Canada, call 1-888-
647-4004.
section 5. service and
Maintenance
5.1

routine Maintenance

Inspect the pump debris tray basket for debris by looking
through the clear pump lid. Remove any debris, because
as debris accumulates, it will begin to block the flow
of water through the pump. Keep the basket clean to
improve the performance of the pump.
1.
Turn off the power to the pump. If the pump is
located below the water level, close the isolation
valves on the suction and discharge sides of the
pump to prevent backflow of water.
2.
Turn the lid's locking ring counter-clockwise
until 'START' aligns with the ports. Carefully
remove the lid. (A tool may used for leverage.)
CaUTion
A misaligned basket will cause the lid to be improperly
seated, allowing an air leak, which could result in pump
damage.
3.
Lift the basket out of the pump.
4.
Dispose of the debris and thoroughly clean the
basket, making sure all the holes are open. Using
a garden hose, spray the basket from the outside
to help clear the holes. Remove any remaining
debris by hand.
5.
Replace the basket in the pump by aligning
the opening with the suction pipe. If aligned
properly, the basket will drop easily into place.
Do not force it into place.
6.
Remove the lid seal and remove debris around the
lid seal seat, as this can allow air to leak into the
system. Clean the lid seal and place it on the lid.
7.
Replace the lid with locking ring. Hand-tighten
the lid to make an air-tight seal. Do not use any
tools to tighten the lid: hand-tighten only.
8.
Verify that all valves have been returned to the
Page 15