Selco GENESIS 1700 TLH Manuel D'instructions page 27

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
5
Arc detachment voltage
Allows you to set the voltage value at which the electric
arc switch-off is forced.
It permits improved management of the various operat-
ing conditions that occur. In the spot welding phase,
for example, a low arc detachment voltage reduces
re-striking of the arc when moving the electrode away
from the piece, reducing spatter, burning and oxidisa-
tion of the piece.
If using electrodes that require high voltages, you are
advised to set a high threshold to prevent arc extinction
during welding.
Never set an arc detachment voltage higher than
the no-load voltage of the power source.
Parameter set in Volts (V).
Minimum 0.0V, Maximum 99.9V, Default 57.0V
6
Antisticking enable
Permits enabling or disabling of the antisticking function.
The antisticking function permits reduction of the weld-
ing current to 0A in the event of a short circuit occurring
between the electrode and the piece, protecting the
gun, electrode and welder and guaranteeing safety in
the condition that has occurred.
ON Antisticking active
OFF Antisticking not active
7
Arc force cut-in threshold
Permits adjustment of the voltage value at which the
power source supplies the current increase typical of
the arc force.
Allows you to obtain different arc dynamics:
Low threshold: infrequent use of arc-force creates a
very stable but not very reactive arc (ideal for expert
welders and for easy-to-weld electrodes).
High threshold: frequent use of arc-force creates a
slightly more unstable but very reactive arc, able to
correct user errors or compensate for the electrode
characteristics (ideal for inexpert welders and for dif-
ficult-to-weld electrodes).
Parameter set in Volts (V).
Minimum 0.0V, Maximum 99.9V, Default 8.0V
8
Dynamic power control (DPC)
It enables the desired V/I characteristic to be selected.
I = C Constant current
The increase or reduction in arc length has no effect on
the welding current required.
Basic, Rutile, Acid, Steel, Cast iron
1÷ 20* Falling characteristic with adjustable slope
The increase in arc length causes a reduction in welding
current (and vice versa) according to the value imposed
by 1 to 20 amps per volt.
Cellulose, Aluminium
P = C* Constant power
The increase in arc length causes a reduction in the
welding current (and vice versa) according to the law:
V.I = K.
Cellulose, Aluminium
*
Increasing the value of the arc force to reduce the risks
of sticking of the electrode.
40
Measurements
Permits selection of the type of measurement to be
shown on the display 4.
0 Real current
1 Real voltage
2 No measurement
Default 0
43
CH1 MIN External parameter
Allows the management of external parameter 1 (mini-
mum value).
44
CH1 MAX External parameter
Allows the management of external parameter 1 (maxi-
mum value).
48
Buzzer volume
Adjustment of the buzzer volume.
Minimum Off, Maximum 10, Default 5
49
Contrast
Adjustment of the LCD display contrast.
Minimum Off, Maximum 15, Default 7
99
Reset
Allows you to re-set all the parameters to the default
values and restore the whole system to the conditions
predefined by Selco.
List of set up parameters (TIG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2
Pre-gas
Allows you to set and adjust the gas flow prior to striking
of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum 0.0s, Maximum 25.0s, Default 0.1s
3
Initial current
Allows regulation of the weld starting current.
Allows a hotter or cooler welding pool to be obtained
immediately after the arc striking.
Parameter setting: Amperes (A) - Percentage (%).
Minimum 3A-1%, Maximum Imax-500%, Default 50%
4
Initial current (%-A)
0=A, 1=%, Default %
5
Slope-up
Allows you to set a gradual passage between the initial
current and the welding current.
Parameter set in seconds (s).
Minimum off, Maximum 10.0s, Default off
6
Bilevel current
Permits adjustment of the secondary current in the
bilevel welding mode.
On first pressing the torch button, the pre-gas starts,
the arc strikes and the initial current will be used when
welding.
27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Genesis 1700 blh

Table des Matières