Cut Out (Framing) Dimensions: Built-In ONLY
Installing in an outdoor cabinet:
A.
This grill must be safely and correctly installed as a built in unit, before being used. Please refer to the chart
below, for correct installation dimensions.
Framing must enclose the grill on the back and sides, but the bottom of the cut-out may be left open. The grill is
supported by the two flanges (left and right), so no support underneath is required. NOTE: please ensure that
fuel line openings provide adequate space for the lines,
CABINET FRAMING DIMENSIONS:
*NOTE: Rear cabinet back splash (if applicable) and counter top must be non-combustible.
A
D
B
C
◼
FUEL TYPE: The following instructions are for a Propane configured grill. Operating Pressure: 11" WC.
◼
HOSE & REGULATOR CART MODELS: Use only the propane hose and regulator supplied with your
Propane grill. For replacement Hose & Regulator assemblies, please contact your local dealer and ask for
part #JF-70. Only use genuine Jackson replacement parts.
◼
HOSE & REGULATOR BUILT IN MODELS: The pressure supplied to the grill must conform to what is
listed on the rating plate of the grills (11" WC). If the supply pressure is great, a regulator must be installed
(regulator not included).
◼
BUILT IN PROPANE GAS HOOK-UP:
The piping up to the gas grill is the responsibility of the qualified installer and piping should be located as
1.
shown below. (Fig. 7)
2. A flexible metal connector pipe is included to simplify the installation of the unit.
3. Connect this flexible metal connector to the flare fitting on the end of the manifold.
4. Connect the other end of the connector to the gas piping.
5. The Flexible connector must not pass through a wall, floor, ceiling or partition, & is protected from
damage.
6. Do not use a hose to connect the unit except to connect the cylinder regulator to the piping system.
7. Do not run hose in areas where heat damage could melt or burn the hose.
E
F
MODEL
Lux
JLS700BI
JLS550BI
*B
*C
*D
*E/F
Propane Gas Connection:
Built In Grill Cutout Dimensions
Cabinets with Non-Combustible Materials
(Eg: metal studs, cement board, tiles, marble)
A
B*
Width
Depth
33"
18 ¾"
24 ¾"
18 ¾"
Depth is measured from the finished face of the
island/cabinet. Notching of countertop front may
be required.
Height is measured from the finished countertop
down.
Minimum distance to rear vertical wall; required
to fully open lid (from cutout).
Minimum distance to side/rear adjacent vertical
combustibles.
9
C*
D*
E*
Height
10"
5 ½"
12"
15.5"
10"
5 ½"
12"
15.5"