11. Error code:

Flash
1
GB
2
3
4
5
6
40
Description
Battery low
Low Battery Fault
High Battery Fault
Current Limit Time-out
Park Brake Fault
Throttle
Initial checkpoints
The batteries are running low.
Recharge the batteries.
The batteries have run out of charge.
Recharge the batteries.
Battery voltage is too high. This may occur
if overcharged &/or traveling down a long
slope.
If traveling down a slope, reduce your
speed to minimize the amount of re-
generative charging.
Check the battery and associated
connections and wiring.
The motor has been exceeding its maxi-
mum current rating for too long. This may
be due to a faulty motor.
Check the motor and associated
connections and wiring.
Turn the controller off, leave for a few
minutes and turn back on again.
Either a park brake release switch is active
or the park brake is faulty.
Check the park brake and associated
connections and wiring.
Ensure any associated switches are in
their correct positions.
The Throttle is out of neutral when turning
the controller on.
Ensure the throttle is in neutral when
turning the controller on.
The Throttle may require
re-calibration.