carbon filter indicator (optional)
OFF
switching on the carbon filter indicator
If you use the recirculation extractor hood, you must use a
carbon filter. In that case, you can switch on the carbon
filter indicator. Press keys
seconds in order to switch on the carbon filter indicator.
The 4 green LEDs light up and the extractor hood gives an
audible signal.

replacing the carbon filter

If the 2
the filter immediately. Place a new carbon filter and erase
the electronic memory by pressing the
approx. 5 seconds. The 2
switching off the carbon filter indicator
Press keys
switch off the carbon filter indicator. The 4 green LEDs light
up and the extractor hood gives an audible signal.
You can check if the carbon filter is switched on by pressing
the keys
seconds. When the carbon filter indicator is switched on the
4 green LEDs light up, otherwise the 4 red.

switch off the key signal

As you press a key, a key signal sounds in confirmation.
Press keys
the in order to switch on the key signal.
Repeat this procedure if you wish to switch off the key
signal again.
GB 6
ON
12h
and
for approx. 5
OFF
ON
nd
red LED in the control panel starts to flash, clean
button for
ON
nd
red LED stops flashing.
and
for approx 5 seconds in order to
OFF
12h
and
continuously for approx 5
12h
en
for 3 seconds continuously on
ON
12h

faults

Please check the following points which may solve the problem, before calling the service
department.
If the connection cable is damaged, it should be replaced by the service department of the
manufacturer or similarly qualified persons in order to prevent dangerous situations from arising.
N N B B : : Disconnect the appliance from the mains before starting any repairs, preferably by removing
the plug from the socket or by setting the isolation switch to zero.
fault
cause
Lighting does not work.
Lamp defective.
NB:
Only use the same type of lamp
with the wattage stated.
1
2
Extractor hood makes a lot of
Discharge duct too long or has
noise.
too many bends.
Motor defective.
No extraction.
Motor or controls defective.
Connection lead defective.
solution
Change the light bulb.
- Gently press the front side of
the window (1) and it should
tilt open slightly (2).
- Open the window fully and fit
a new 20 W halogen bulb.
Note: do not touch the bulb's
glass with your fingers.
- Gently push the window
closed again.
Change the discharge duct
(see installation instructions).
Phone the Service department.
Phone the Service department.
Phone the Service department.
GB 7