14. Troubleshooting Guide

Fault
Cause
Unit doesn't blast,
warning lamp flashing.
Air flow present but no
sand coming through.
No air, no sand.
On/Off switch doesn't
work.
Basket shakes,
doesn't move.
Blasting chamber gets
too dusty.
Consumption of blast-
ing material too high.
Objects fall out of the
basket.
Blasting time too long
/ reduced blasting
effect.
Extraction unit still
runs even when
blasting has been
interrupted.
Heavy dust build-up
during blasting.
Switch for external
extraction does not
work.
EN
Glass pane is not closed.
Magnet (Fig. 42-A) is missing.
Protective switch is defect.
Amount of sand too low.
Filter on suction point of suc-
tion pipe is blocked.
Suction pipe defect.
Nozzle is blocked.
No power connection.
Unit fuse (Fig. 13-B) is defect.
Basket is stuck mechanically.
Too little suction power.
Extraction unit blocked.
Suction power is too high.
Too many objects.
The blasting cones are shelter-
ing the objects.
Too little working pressure.
Too great distance from nozzle.
Too little blasting material in
unit.
Blasting material lead pipe is
blocked / defect.
Blasting nozzle is split.
Air power of the compressor is
too low.
A certain run-on time is normal
in order to remove any dust still
present in the chamber.
The switch for the external
extraction unit (Fig. 18-F) was
reactivated.
No extraction unit connected.
Extraction power too weak.
Extraction unit is not controlled
by blasting unit.
Remedy
Close the pane.
Replace the magnet (see spare parts list).
Exchange during service.
Fill with more sand.
Clean the filter.
Exchange the suction pipe.
Open the blasting nozzle unit (Fig. 15-A) and clean the nozzle.
Connect to the power supply.
Change fuse (Fig. 13-B) - replacement fuse in set. If it happens
again >>> repair.
Release by removing and replacing the basket.
Raise suction power on extraction unit.
Increase suction performance by closing the air inlet boreholes un-
der the glass holder (Fig. 42-B) (with the supplied magnetic strip).
Clean extraction unit.
Reduce suction power.
Warning: too little suction power can lead to dirty blasting material.
Reduce to a maximum of 6 objects.
Remove blasting cones before starting.
Increase working pressure >>> recommended working pressure:
4 - 5 bar [58 - 72.5 psi].
Move nozzle further forward.
Unit should be filled with min. 4 - 5 kg blasting material.
Remove sand and check / replace lead pipe.
Replace nozzles.
Dehydrate the compressor. Use a more powerful unit.
Regulate the run-on time between 5 and 30 seconds via the control
on the back of the unit (Fig. 21).
Switch off the external extraction unit.
Connect an extraction unit.
Close the air holes (Fig. 42-B).
Increase extraction power.
Connect the extraction unit power cable to the blasting
unit.