Ordinary Maintenance; Spare Parts And Accessories; Periodical Operations For Ordinary Maintenance; Max Pressure Switch Reset - wigam EASYREC 120R100 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EASYREC120
8.

Ordinary maintenance

8.1.
S
PARE PARTS AND ACCESSORIES
n°1
MG111 Filter drier
n°1
XH412 Filter drier
n°1
G19020 Kit of 10 gaskets for flexible hose with ¼" SAE connections
8.2.
P
ERIODICAL OPERATIONS FOR ORDINARY MAINTENANCE
a)
Replace the swivel connections gaskets of the flexible hoses as soon as they show worn marks.
b)
Replace the filter each time a different type of refrigerant is used and at least once every six
months.
9.

Max pressure switch reset

When a pressure of 38,5 BAR is reached, the max pressure switch, which is in the unit, operates by
restraining all functions; the unit will automatically shut itself off and the Red Alarm Light will turn on.
If the compressor needs to be restarted, please find out the cause first, then reduce the internal pressure
below 25 bar. Press the START key to restart the compressor.
10.

Technical features

Refrigerants
Power
Motor
Motor speed
Maximal
current draw
Compressor
Automatic
safety shut-off
Recovery rate
(kg/min)
Operating
temperature
Dimensions
Weight
WIGAM
USER'S MANUAL
Category III: R12, R134a, R401C, R406A, R500
Category IV: R22, R401A, R401B, R402B, R407C,
R407D, R408A, R409A, R411A, R411B,
R412A, R502, R509
Category V: R402A, R404A, R407A, R407B, R410A, R507
220-240VAC 50~60Hz
370 W AC 4 Pole start capacitor running capacitor
1450 rpm@50Hz
5A
Oil-less, air-cooled, piston
38.5 bar/3850kPa(558 psi)
Category III
Vapor
0.23Kg/min
Liquid
1.57Kg/min
Push/pull
4.6Kg/min
0 ~ 40℃
500 mm×250 mm×350 mm
17 kg
ENGLISH
1750 rpm@60Hz
8A
Category IV
Category V
0.25Kg/min
0.26Kg/min
1.81Kg/min
1.85Kg/min
5.57Kg/min
6.22Kg/min