To maximize recovery rates, use the shortest possible length of 3/8" or larger hose.
u) While recovering large amounts of liquid, use the liquid Push/Pull method.
v) After recovering, make sure there is no refrigerant left in the unit. Read the Self-Purging Method
carefully. If liquid refrigerant remains in the unit, it can expand and damage the components.
w) If the unit is to be stored or not used for any length of time, we recommend that it be completely
evacuated of any residual refrigerant and purged with dry nitrogen.
x) We suggest to use the hose with valve in order to reduce the loss of the refrigerant