GBD F4 PLUS Instructions D'installation page 15

Masquer les pouces Voir aussi pour F4 PLUS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

F4 PLUS
MOTOR 1 OPENING
DIP1_4
LIMIT SWITCH
MOTOR 1 CLOSING
DIP1_5
LIMIT SWITCH
MOTOR 2 OPENING
DIP1_6
LIMIT SWITCH
MOTOR 2 CLOSING
DIP1_7
LIMIT SWITCH
DIP1_8
PHOTOCELL
TERMINALS 7-8
DIP1_9
FUNCTIONING
HYDRAULIC
DIP1_10
LOCK
RETENTION
9 - DIP SWITCH DIP2
The settings are stored during the rest phase (gate closed).
The default settings are highlighted in the boxes with grey background.
DIP
Function
TERMINAL 23
DIP2_1
FUNCTIONING
TERMINAL M4
DIP2_2
FUNCTIONING
DIP2_3
DIP2_4
ON
Disables the limit switch input
OFF
Enables the limit switch input
ON
Disables the limit switch input
OFF
Enables the limit switch input
ON
Disables the limit switch input
OFF
Enables the limit switch input
ON
Disables the limit switch input
OFF
Enables the limit switch input
ON
Disables the photocell input
OFF
Enables the photocell input
The outputs 7-8 of the terminal board are used to control a FLASHLIGHT
ON
equipped with its own flashing circuit.
The outputs 7-8 of the terminal board are used to control a COURTESY LIGHT
that remains active for 2 minutes after the motor movement.
OFF
In this mode, the terminals 28-29 can be used to connect a FLASHLIGHT
without a flashing circuit.
For HYDRAULIC motors only.
If the gate has not performed any operation in the last 5 hours, a 2-second
ON
closing pulse is given.
THE STOP KEY DISABLES THE FUNCTION.
OFF
HYDRAULIC RETENTION deactivated.
Description
Status
The STOP input (23) functions as FRAME and when intercepted, will invert the
motion for 2 seconds in order to free the obstacle.
ON
See also jumper SW15.
The STOP input (23) functions as STOP and when intercepted, will lock the
OFF
motion. See also jumper SW15.
ON
Terminal M4 operates as WARNING LIGHT.
OFF
Terminal M4 operates as FLASHING LIGHT.
NOT USED
In the case of a system with only one
motor and using the limit switches,
the DIP switches 4, 5, 6 and 7 are
to be set to OFF; while if using only
one type of limit switch (e.g. FCAM1
and/or FCCM1), enable only the
corresponding DIP switch (set to OFF).
15
UK

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

As05950

Table des Matières