6 - PROTECTION FUSES

Position
Value
F1
5A
F2
160mA
7 - WARNING LEDs
LED
Colour
L1
RED
L2
RED
L3
RED
L4
RED
L5
RED
L6
GREEN
L8
GREEN
L10
RED
Type
Description
Protects the circuit board and the motors.
FAST
FAST
Protects the circuit board and the accessories.
Signal
Description
Always on. Goes off when the CLOSING LIMIT SWITCH of motor 2
FCCM2
is reached.
Always on. Goes off when the OPENING LIMIT SWITCH of motor 2
FCAM2
is reached.
Always on. Goes off when the CLOSING LIMIT SWITCH of motor 1
FCCM2
is reached.
Always on. Goes off when the OPENING LIMIT SWITCH of motor 1
FCAM1
is reached.
PHOTO
Always on. Goes off when the photocell is intercepted interrupting the beam.
Comes on when the START command is activated and goes off when
START
released.
Comes on when the PEDESTRIAN start command is activated and goes off
PED
when released.
SAF. / STOP
Always on. It turns off after STOP/COSTA INPUT intervention.