Sound alarm with LED
- When an audible signal is desired in combination
with the memory LED, turn the alignment sound
switch to ON.
When the alarm memory function is not used,
leave the receiver terminal 11 unconnected.
(Logic switch can be in either position.)
Estimated battery life
PB-IN-50HFA
No. of pair
Md AA
Gel Cell
0.5Ah
1
8 hr
2
-
4
-
8
-
PB-IN-100HFA
No. of pair
Md AA
Gel Cell
0.5Ah
1
7 hr
2
-
4
-
8
-
PB-IN-200HFA
No. of pair
Md AA
Gel Cell
0.5Ah
1
5 hr
2
-
4
-
8
-
Unit should be connected to a listed class 2 power
source capable of providing standby power for at
minimum 4 hours.
Troubleshooting
Operation LED does not light up
1. Disruption of power or inadequate power.
- Correct power supply.
2. Bad wiring connections or broken wire, short-circuit.
- Check and correct wiring.
Receiver Alarm LED does not light up when the beam
is interrupted.
1. Disruption of power or inadequate power.
- Correct power supply.
2. Bad wiring connections or broken wire, short-
Gel Cell
circuit.
1.0Ah
5.0Ah
- Check and correct wiring.
16 hr
83 hr
3. Beam reflection is flooding receiver.
- Remove the reflecting object. Contact TAKEX for
8 hr
41 hr
further remedies.
-
20 hr
4. Four beams are not interrupted simultaneously.
- Ensure all beams are interrupted at same time.
-
10 hr
5. Beam interruption time is shorter than response
time.
- Adjust response time.
Gel Cell
Receiver Alarm LED stays on
1.0Ah
5.0Ah
1. Alignment is out.
14 hr
71 hr
- Check and adjust.
2. Obstruction between transmitter and receiver.
7 hr
35 hr
- Check site / remove any possible obstacles.
-
17 hr
3. Optical parts of units are soiled.
- Clean the optical parts with a soft cloth.
-
8 hr
4. Frequency channel setting on transmitter does not
match with that on receiver.
- Readjust to the same channel.
Gel Cell
Intermittent alarm
1.0Ah
5.0Ah
1. Bad wiring connection.
11 hr
58 hr
- Check again.
2. Change of supply voltage.
5 hr
29 hr
- Stabilize supply voltage.
-
14 hr
3. Obstructing object between transmitter and
receiver.
-
7 hr
- Remove the obstruction.
4. Transient spikes on supply cables.
- Relocate.
5. Loose installation of transmitter and receiver.
- Tighten.
6. Optical parts of units are soiled.
- Clean the optical parts with a soft cloth.
7. Poor alignment.
- Check and adjust again.
8. Animals pass through the four beams.
- Change environment of the installation.
9. Beam power switch is set to L; not enough
sensitivity.
- Set beam power switch to H and make the unit
gain-locked with the receiver cover detached.
Approvals
CE: conform
National approval conditions relating to the use of the
product must be followed.
.......................................... Contact: 30V (AC/DC), 0.5A
⑥
Specifications
Detection system
Infrared beam
Double modulation pulsed
Protection distance
- PB-IN- 50HFA outdoor 165' ( 50 m)
...........................
...........................
- PB-IN-100HFA outdoor
- PB-IN-200HFA outdoor
...........................
Max. beam range
..................................
- PB-IN- 50HFA
..................................
- PB-IN-100HFA
- PB-IN-200HFA
..................................
Response time ................................. 0.05sec. to 0.7sec.
Supply voltage .................. 12V to 30VDC (non-polarity)
Current consumption
................................................... 95mA
- PB-IN- 50HFA
.................................................. 105mA
- PB-IN-100HFA
.................................................. 120mA
- PB-IN-200HFA
Alarm output ....................................... Dry contact relay:
..................................................... NC or NO switchover
.............................. Reset: Interruption time (Min 2sec.)
............................................. Contact: 30V (AC/DC), 1A
Environmental ouput .........................Dry contact
................................................... NC or NO switchover
...... Contact operation: Output when weather condition
.......................................gets worse
Tamper output ...................................... Dry contact NC
................................Contact operation:
............................................. receiver cover is detached
.......................................... Contact: 30V (AC/DC), 0.1A
Alarm LED ...................Red LED (Receiver) lights when
........................................................ an alarm is initiated
Attenuation LED ..........Red LED (Receiver) lights when
........................................ beam receiption is attenuated
Functions ............ Modulated beam frequency selection
.............................................................. Sound indicator
................................................... Environmental module
............................................... Alarm memory indication
.........................................................
...................................................Auto-gain lock function
.................................................................... Monitor jack
Ambient temperature range .................
.............................................................
..................................................
Ingress protection
Mounting position .............................................. Outdoor
Wiring ............................................................. Terminals
Weight
- Transmitter ..............................................
- Receiver ...............................................
Appearance ............................... PC resin (ruby-colored)
Details for ordering
PB-IN- 50HFA Photoelectric beam sensor ( 50 m)
PB-IN-100HFA Photoelectric beam sensor (100 m)
PB-IN-200HFA Photoelectric beam sensor (200 m)
BP-200F Pole cover (2 pcs./set)
HTF-24 Heater (2 pcs./set) 24 V DC: 860 mA
Limited warranty
TAKEX products are warranted to be free from defects
in material and workmanship for 12 months from
original date of shipment. Our warranty does not cover
damage or failure caused by Acts of God, abuse,
misuse, abnormal usage, faulty installation, improper
maintenance or any repairs other than those provided
by TAKEX. All implied warranties with respect to TAKEX,
including implied warranties for merchantability and
implied warranties for fitness, are limited in duration
to 12 months from original date of shipment. During
the Warranty Period, TAKEX will repair or replace,
at its sole option, free of charge, any defective parts
returned prepaid. Please provide the model number
of the products, original date of shipment and nature
of difficulty being experienced. There will be charges
rendered for product repairs made after our Warranty
Period has expired.
Near infrared beam
interruption system
beam by LED
330' (100 m)
660' (200 m)
1,650' ( 500 m)
3,300' (1,000 m)
6,600' (2,000 m)
Output when
Programmed AGC
-31ºF to +151ºF
(-35ºC to +66ºC)
IP55
42 oz (1.2 kg)
45.5 oz (1.3 kg)