Figure 2-118 shows the array of status indicator LEDs on the PROFINET board. For details on the
use of these LEDs, please refer to the IND570 PLC Interface Manual, available for download at
www.mt.com/IND570.
2.4.6.10.1.
Installation in the Harsh Enclosure
Available Ports
Both RJ45 ports on the PROFINET option are active and can be used when installed into an
IND570. With both ports available, ring and linear PROFINET topographies can be supported with
IND570 terminals.
PROFINET Connector for Harsh Installation
Due to space limitations inside the harsh enclosure, connection inside the IND570 harsh enclosure
requires use of an RJ45 connector (plug and strain gauge) with a total length less than 25mm
(1"). Note: For installations that require the use of an RJ45 connector specified by Siemens,
Siemens offers a special right-angle connector with the appropriate length (<25mm) for use in the
harsh IND570 enclosure (Figure 2-119). However, if this Siemens connector (part number is
6GK19011BB202AA0) is used only one of the ports on the IND570 PROFINET interface is
accessible. In this case, only a single-port topology will be possible.
2-66
METTLER TOLEDO IND570 Terminal Installation Manual
Link Activity
Figure 2-118: PROFINET Status Indicator LEDs
Note: There is a physical restriction within the IND570 harsh enclosure that will prohibit the use
of some forms of RJ45 connectors. Please refer to the following section, PROFINET Connector
for Harsh Installation, for additional details.
Figure 2-119: Siemens Right-Angle Connector for Harsh Installation of PROFINET Option
[Not used]
Communication Status
Module Status
30205319
|
11
|
07/2019