In the event where the distance between the pushing points, shown as "In", is different from that indicated in
the table below, a longer bar will need to be used, made to the necessary length.
Top-hung outward opening window with 2 or more pushing points: Length of the connection bar
In = Interasse
L = In - 105 mm
Top-hung outward opening window with 2 or more pushing points
Make the connection bar to measure
Distance "In" betwe-
Bar length "L" in
en centres in mm.
mm.
1000
891
1500
1391
2000
1891
2500
2391
3000
2891
Kit of connection collars
Drill the holes for fixing to the collars
Article
MA00AB01N0G00
MA00AB02N0G00
MA00AB03N0G00
MA00AB04N0G00
MA00AB05N0G00
MA00XX01N0G00
L= In - 109 mm