(4) If there's sound of liquid shock when the compressor is running, then stop the
air conditioner immediately. Wait until the electric heating belt is heated
enough, and then restart the air conditioner.
(5) Feel the air flow of the indoor unit to see if it is normal.
(6) Press the swing button or speed control button on remote control or wired
control to see if the fan can run normally.
Notice:
①. If you use remote control to turn off the unit and then immediately turn the
unit on again, compressor will need 3min to restart. Even if you press
―ON/OFF‖ button on the remote control, it won't be started up right away.
②. If there's no display on the wired control, it's probably because the
connection wire between the indoor unit and wired control is not
connected. Please check again.

4 Operation Specification

Refer to the wired controller or remote controller manual.
DC Inverter U-match Series Cassette Type Unit
51