Ebode IR Link Série Guide Utilisateur page 7

Masquer les pouces Voir aussi pour IR Link Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
NOTE: Unit will not work with certain brands & models that operate at higher frequencies (e.g.
B&O). Contact ebode Technical Support for more information.
Cable requirements for long lengths to remote rooms:
3-conductor, 24AWG/0,2mm2 solid or stranded wire up to 50m, 22AWG/0,35mm2 up to 100m,
20AWG/0,5mm2 up to 200m and 18AWG/1mm2 up to 300m (unshielded OK).
Maximum transmission length: 300m with category cable (UTP, use white striped together for
GND, and use 2 solid colours for IR and 2 solid colours for 12VDC). In case of STATUS wiring, use 1
solid wire for IR and 1 solid wire for Status.
In case of long run un-shielded cable (> 25m), it may be necessary to connect a 470 Ohm
1/8Watt resistor in parallel between IR and GND at the IRHUB connecting block.
IRHUB4 Connecting Hub
x
1x Power: 230V~50Hz, 12VDC 200mA (supplied)
x
1x 4-Way screw terminal for IR, GND, 12VDC and Status
x
1x Power Status JP2 input: 5 – 12VDC @ 10mA minimum or 5 – 12VAC at 47-63HZ
x
1x JP to C-plug 2.1mm cable, centre positive (not supplied)
x
4x IRED jacks: 3.5mm mono TS-plug
x
1x IR Receiver jack: 3.5mm TRRS-plug
x
Dimensions: 60x55x20 mm
7-4-2011 Rev 2
7
IR Link Pro Mini

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ir link pro mini

Table des Matières