Chapitre 6
Programmation
Tableau 75 - Groupe Motor Protection
Puissance
Puissance
réactive – (BA)
apparente (BA)
Motor Fault Enable
Motor Fault Enable Motor Fault Enable Motor Fault Enable Starter Fault Enable Motor Fault Enable Starter Fault Enable Motor Fault Enable
Motor Alarm Enable Motor Alarm Enable
Motor Restart
Motor Restart Enable
Enable
-MVAR Ov F Level
MVA Ov F Level
-MVAR Ov F Delay
MVA Ov F Delay
-MVAR Ov A Level
MVA Ov A Level
-MVAR Ov A Delay
MVA Ov A Delay
+MVAR Un F Level
MVA Un F Level
-MVAR Un F Delay
MVA Un F Delay
-MVAR Un A Level
MVA Un A Level
-MVAR Un A Delay
MVA Un A Delay
Fréquence réseau (BA)
Starter Fault Enable
Starter Alarm Enable
Starter Restart Enable
Frequency High F Level
Frequency High F Delay
Frequency High A Level
Frequency High A Delay
Frequency Low F Level
Frequency Low F Delay
Frequency Low A Level
Frequency Low A Delay
162
Paramètres du groupe Motor Protection
PF en avance
PF en retard (BA)
(BA)
Motor Alarm
Motor Alarm
Enable
Enable
Motor Restart
Motor Restart
Enable
Enable
Lead PF F Level
Lag PF F Level
Lead PF F Delay
Lag PF F Delay
Lead PF A Level
Lag PF A Level
Lead PF A Delay
Lag PF A Delay
Lead PF F Level
Lag PF F Level
Lead PF F Delay
Lag PF F Delay
Lead PF A Level
Lag PF A Level
Lead PF A Delay
Lag PF A Delay
Maintenance
Motor Fault Enable (BA)
Motor Alarm Enable (BA)
Motor Restart Enable (BA)
PM Hours (BA)
PM Starts (BA)
Time to PM (MBA)
Starts to PM (MBA)
Starts per Hour (MBA)
Tableau 76 - Paramètres du groupe Communications
Masques de communication (BA)
Logic Mask
Logic Mask Act
Write Mask Cfg
Write Mask Act
Port Mask Act
Publication Rockwell Automation 150-UM011E-FR-P - Avril 2021
Déséquilibre de
Déséquilibre de
tension (BA)
courant (BA)
Motor Alarm
Starter Alarm Enable
Enable
Motor Restart
Enable
Starter Restart
Enable
Current Imbal F
Level
Voltage Unbal F
Current Imbal F
Level
Delay
Voltage Unbal F
Current Imbal A
Delay
Level
Voltage Unbal A
Current Imbal A
Level
Delay
Voltage Unbal A
Delay
Historique (MBA)
Redémarrage (BA)
Fault 1
Motor Restart Enable
Fault 2
Starter Restart Enable
Fault 3
Restart Attempts
Fault 4
Restart Delay
Fault 5
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Paramètres du groupe Communications
Data In A1
Data In A2
Data In B1
Data In B2
Data In C1
Data In C2
Data In D1
Data In D2
THD – tension (BA) THD – courant (BA)
Starter Alarm Enable Motor Alarm Enable
Motor Restart
Enable
Starter Restart
Enable
THD I F Level
THD V F Level
THD I F Delay
THD V F Delay
THD I A Level
THD V A Level
THD I A Delay
THD V A Delay
Rotor bloqué (BA)
Motor Fault Enable
Motor Alarm Enable
Motor Restart
Enable
Locked Rotor F Level
Locked Rotor F
Delay
Locked Rotor A Level
Locked Rotor A
Delay
Datalinks (BA)
Data Out A1
Data Out A2
Data Out B1
Data Out B2
Data Out C1
Data Out C2
Data Out D1
Data Out D2