Problem
After emptying the
used coffee collec-
tor (7), the warning
message remains
displayed on the
screen.
After cleaning the
cleaning drawer (8),
the warning mes-
sage remains dis-
played on the
screen.
A power cut occurs
during the cycle.
There is water un-
derneath the ap-
pliance.
A "Fault n° xxx" mes-
sage appears on the
screen.
i
Tip : Programming problems are often resolved by unplugging the appliance for about one
minute and then plugging it in again.
!
Caution : Do not carry out any work yourself on the appliance !
34
Probable causes
The used coffee collector is not fit-
ted correctly.
The used coffee collector has been
refitted too quickly.
The cleaning drawer is not fitted
correctly.
The cleaning drawer has been refit-
ted too quickly.
The drip tray (23) is not correctly fit-
ted or is overflowing.
Programme error.
Use and maintenance / SERIE EA 82xx
Corrective actions
 Refit the used coffee collector
correctly.
 In general wait for at least 6 se-
conds before refitting the empty
collector.
 Refit the cleaning drawer cor-
rectly.
 In general wait for at least 6
seconds before refitting the dra-
wer.
 The appliance is automatically
reinitialised when it is switched
back on.
 Check that the drip tray has
been fitted correctly and empty it
if required.
 Unplug the appliance for 20
seconds. Remove the tank and
take out the Claris cartridge if
fitted (do not remove the tank
too soon). Plug in the appliance
and refit the tank.
If the message is still displayed,
write down the fault number and
contact the KRUPS Customer
Service.