Swinging boom sensor input N.C.
 swingin boom sensor not mounted or disabled
 automation stops immediately in case of swinging boom opened
The following table gives the 4th level functions and the single parameters.
= DEFAULT value set in factory.
Par
Function
Communication protocol

(see notes after the table)
Setting

U-LINK mode

Setting U-LINK adress

Setting Modbus/RTU ID

Setting MODBUS RTU speed

Operation counter
Error History

(see notes after the table)
NOTES:
:
·
Setting communication protocol. Set value always same to Master and Slave.

:
·
The error list and the occurrence are alternatively shown .
Such as:
alternating


<------->

10. CAP LIGHTS MAXIMA ULTRA 36

On the MAXIMA ULTRA 36 barrier, it is possible to associate a color to the cap when the bar is open and another for all other cases (see para-
meters CO / CC 1st level programming). In the semaphore function, which can be set with Fp = 2, it is possible to link the color (red / green)
to the PDM signal status, regardless of the status of the boom.
Contact PDM
Parameter Pd
Open
0
Close
0
Open
1
Close
1
In the absence of errors or diagnostic events the colors on the cap are fi xed.
In the presence of error conditions or diagnostic events, ONLY with the stop bar there are fl ashes with color relating to the error code shown
in the table.
COLOR
VIOLET
Fuse F3 or F4 burned / stopped active / active fracture input
ORANGE
Intervention of the reverser with reopening / number of anomalous encoder pulses
YELLOW
Timeout in opening or closing / limit switch both active
LIGHT BLUE
Reached the number of cycles scheduled for maintenance
BLUE
Lack of communication with the inverter
WHITE
Other error
Control unit
4TH
9.5
LEVEL PROGRAMMING
Settable data
: disabled
: U-LINK
: Modbus/RTU
: Slave
: Master
: Slave for opposing barriers
: Master for opposing barriers

: For Master
: For Slave
: 19 200 baud
: 38 400 baud
Operation counter. Read-only parameter, expressed in hundreds of
operations.
xx: error list and occurrence alternatively shown
(see chapter 14 "ERROR HANDLING")
: no history clear
: history is clear
Cap color
Green
Red
Red
Green
ERROR/EVENT
- 29 -
= parameter value set during installation: must be indicated
if DEFAULT value is modifi ed.
EN





