The following table gives the 2nd level functions and the single settable parameters.
= DEFAULT value set in factory.
Par
Function

Maximum operating time (sec.)
Request for maintenance (see

notes after the table)
Programming maintenance

cycles in thousands (see notes
after the table)
Programming maintenance

cycles in millions (see notes
after the table)


Output 2, Output 3,

Output 4, Output 5

Termon (see notes after the ta-

ble)

UPS (see notes after the table)

Exiting the menu/saving
NOTES:

·
: Request for maintenance
: the request for maintenance is not active.
: at the end of the countdown, by means of counters  and , one of the programmed outputs is activated (see parameter ,,,)
: at the end of the countdown, by means of counters  and , one of the programmed outputs is activated (see parameter ,,,)
and the bar lights fl ash twice.


and
·
: Programming maintenance cycles in thousands and millions
By the combination of the two parameters the countdown can be set after which a request for maintenance is signalled.
Thousands can be set with the  parameter, millions with the  parameter.
Example: to set 275 000 maintenance manoeuvres set  on 0.2 and  on 75.
The value displayed in the parameters updates along with the manoeuvres.

·
: TERMON (integrated motor heater system).
: system is always ON. Must be used only with maximum ambient temperature less than +10°C
WARNING: ambient temperatures >10°C may cause overheating and damages to the motor, not covered by warranty
: system is actived depending on motor temperature, measured by a temperature sensor (option). In case of sensor failure, system
reverts to setup 
Control unit
9.3
2ND
LEVEL PROGRAMMING
= parameter value set during installation: must be indicated if DEFAULT value is modifi ed.
-
: disabled
: active on the confi gured outputs
: active on the confi gured outputs and the bar lights fl ash twice

..
: request for maintenance
: photocell triggering
: encoder triggering
: PDM contact actuated
: boom closed
: boom opened
: stop contact actuated
: warning fl ash
: Boom locking device
: opened triggering
: closed contact activated
: start triggering
: FRAC triggering
: UPS triggering
: second radio channel triggering (only OUT 5)
: Disabled
: Enabled and always active
: Enabled when needed by means of NTC sensor connected between
8k2 and COM input terminal
: disabled
: enabled, opens automatically during mains failure
: enabled, closes automatically during mains failure
ATTENTION:THIS SELECTION MAY BE DANGEROUS
Pressing the "F" key, the programming menu is quit and the changes
saved.