configuration, select the output and press the OK key. The
receiver displays the previously set function mode as the first
option.
3) If you try to configure an output which is not provided with a MOP
optional module, the "module not present" error message will be
displayed.
4) In the case of PC operation malfunctions, or any communication
failure between Securbase and RTD-CA, the RTD-CA receiver
stand-alone functions remain active, so the receiver can continue
to check the cards recorded in its memory. It is therefore advisable
to copy the most frequently used or most important cards from the
Securbase database to the RTD-CA memory. Make reference to
the Securbase Instructions for further information.
5) The following table indicates the memory capacity of the RTD-CA
versions:
RTD-CA
Max. no. cards or
transmitters enabled
512
819
2048
2500
Each storage takes up a memory location, regardless of the type of
device entered, therefore if for example 400 transmitters are stored in
the memory of an RTD-CA 512, 419 locations will be left available to
memorise the cards (819-400=419).
Configure RTD-CA:
Allows you to set the general system functions.
Language: select one of the languages available (Italian,
French, German, English, Spanish).
Password: use the + and - buttons to enter a password
consisting of 4 digits (from 0 to 9). If a value other than the
default value (0000) is entered, the access password will be
requested for the subsequent configuration attempt. If you do
not wish to protect receiver programming by means of a
password, re-enter default value 0000.
6) RADIO TRANSMITTER CLONING
ADDITIONAL CLONING WITH MASTER
For practical clone generation by means of the master transmitter
(marked by the key label), refer to the instructions on the UNIRADIO
device or observe the following simplified procedure:
1) Switch UNIRADIO on and wait for the welcome message.
2) Use the <arrow up> and <arrow down> keys to select item <go
the menu number>.
3) Press <enter>.
4) When in the subsequent menu, type number 2122 and press
<enter>.
5) Follow the instructions appearing on the UNIRADIO display.
CODE READING
In the case where a receiver code in not known, reading can be
obtained by proceeding in the following way:
1) Switch UNIRADIO on and wait for the welcome message.
2) Use the <arrow up> and <arrow down> keys to select item <go
the menu number>.
3) Press <enter>.
4) When in the subsequent menu, type number 225 and press
<enter>.
5) Follow the instructions appearing on the UNIRADIO display.
ADDITIONAL CLONING WITH CODE
Once the key code has been read, it is advisable to write it down on
the appropriate card supplied before giving it to the user (fig. 7).
For practical clone generation, refer to the instructions on the UNIRADIO
device or, for additional clones, observe the following simplified
procedure:
1) Switch UNIRADIO on and wait for the welcome message.
2) Use the <arrow up> and <arrow down> keys to select item <go
the menu number>.
3) Press <enter>.
4) When in the subsequent menu, type number 2121 and press
<enter>.
5) Follow the instructions appearing on the UNIRADIO display.
The UNIRADIO device (Fig.6) also allows to read and copy the lists of
the transmitters memorised from one RTD-CA to another.
On the other hand, the UNIRADIO device does not allow to modify the
INSTALLATION MANUAL
Max. no.
Total
transmitters
512
819
2048
3270
lists.
UNIPRO does not support the RTD-CA output configuration.
The receiver does not supply the UNIPRO programmer, which therefore
requires an appropriate supply unit or charged batteries.
7) CONNECTION TO PC
The RTD-CA system can be interfaced with a personal computer for
access monitoring (fig. 4-5).
In this case the following accessories are required:
COMPASS-232 Interface for PC: provides serial connection between
RTD-CA and PC. A maximum number of 20 outputs can be managed.
NOTE: Connect a 120 Ohm/0,25W resistor between terminals 7 and
8 on the farthest RTD-CA along the line, as shown in fig. 5.
SECURBASE Monitoring software, having the following main functions:
Increase in the maximum number of cards which can be memorised
and managed (with the only limitation of the PC memory)
Use of access enabling time bands (the user can only have access
within a specified time band)
Use of access enabling calendar (the user can only have access
in predefined days).
Anti-passback: by installing an additional RTD-CA/Compass-
Reader set in output, you can check that a card has been taken out
Real-time display of accesses
Real-time display of card owner's personal details
Possible setting of parameters of connected readers
Access recording with possible search and printout.
Card management in Securbase takes place by means of a system
reader, consisting of any RTD-CA/Compass-Reader set.
See Configuration, Access control and System reader menus.
COMPASS READER
The Compass-Reader proximity card reader is provided with a LED
which changes colour depending on the output status:
Green: access free or opening contact picked up
Red: access forbidden
Yellow: normal operation (waiting for code)
Yellow, blinking: waiting for Securbase enquiry
Yellow/Green, blinking: system reader
If more than one exit is configured for access control, the LED will only
respond to the status of output 4.
It is however possible to control more than one RTD-CA output using
a single Compass-Reader.
This function turns out to be particularly useful in the case of close-up
access points, where separate card groups can be enabled for each
RTD-CA output.
8) MAINTENANCE
The maintenance of the system should only be carried out by
qualified personnel regularly. The MITTO transmitters are supplied
by two 3V lithium battiers (type CR2016).The TRC transmitters are
powered by a 12V alkaline battery.When replacing the batteries type
CR2016 do not touch the poles with thehands.
Any reduction in the transmitter capacity may be due to the batteries
getting flat. When the led of the transmitter flashes, it means that the
batteries are
flat and must be replaced.
9) DISPOSAL
ATTENTION: disposal should only be carried out by qualified
personnel.
Materials must be disposed of in conformity with the current regulations.
In case of disposal, the system components do not entail any particular
risks or danger. In case of recovered materials, these should be sorted
out by type (electrical components, copper, aluminium, plastic etc.).
For battery disposal, refer to the current regulations.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any
alterations deemed appropriate for the technical, manufacturing
and commercial improvement of the product, while leaving its
essential features unchanged, at any time and without undertaking
to update the present publication.
ENGLISH