Parallel Operation Port
The parallel operation port allows you to connect two P3000
model inverter generators with an Briggs & Stratton
approved parallel operation kit (optional equipment). When
running in parallel, the total output of power is up to 4,800
watts (4.8 kW).

STATSTATION™

The control panel has a built in LCD display (A) to monitor
the following features:
D
F
E
• Load Monitor (Total Generator Load)
• Hour Meter (Total Generator Hours)
• Maintenance Reminder (Engine Maintenance)
Load Monitor
The load monitor measures the output wattage (generator
load) of all the generator receptacles and will display the
percentage of total generator load.
Hour Meter
The LCD on the control panel also has a built in hour meter
that displays and records how many hours your generator
has run (up to 999.9).
16
Maintenance Reminder
The LCD on the control panel also has a built in maintenance
reminder to alert you to change air filter, change oil, and
change spark plug. The LCD display will flash every 50 hours
for the different maintenance intervals. See Maintenance
Schedule for different maintenance intervals.
Pressing the "View" button (B) will toggle between the
flashing load percentage and the flashing hour display. Once
maintenance has been performed, you must push and hold
the "View" button on the control panel for a minimum of
3 seconds to stop the display from flashing and return it to
normal operation.
C
Output Indicator
The green LED output indicator light (C) comes on when the
A
generator is operating normally. It indicates that the
generator is producing power at the receptacles.
B
Overload Alarm
The red LED overload alarm light (D) comes on and cuts
power to the receptacles if you overload the generator. The
green output indicator light will also go off. If the generator
was overloaded, you must turn off and unplug all electrical
loads, press the "Reset" button (E) on the generator control
panel and then plug in and restart electrical loads one at a
time to continue in normal operating mode.
Low Oil Indicator
The low oil indicator system is designed to prevent engine
damage caused by not enough engine oil. If the engine oil
level drops below a preset level, the yellow LED low oil
indicator light (F) comes on and an oil level switch will stop
the engine. If the engine stops or the yellow LED low oil
indicator light comes on when you pull the recoil handle,
check the engine oil level.