Cord Sets and Receptacles

Use only high quality, well-insulated, grounded extension
cords with the generator's receptacles. Inspect extension
cords before each use.
Check the ratings of all extension cords before you use
them. Check the operator's manuals of devices for the
manufacturer's recommendations.
WARNING Damaged or overloaded electrical cords
could overheat, arc, and burn resulting in death
or serious injury.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
• Inspect cord sets before each use.
120 Volt AC, 30 Amp Locking Receptacle
Use a NEMA L5–30 plug with this receptacle. Connect a
3–wire cord set rated for 125 Volt AC loads at 30 Amps to
the plug.
3-Wire Cord Set
Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 2,600 watts (2.6 kW) of power at
21.6 Amps.
NOTICE Receptacles may be marked with rating value
greater than generator output capacity.
• NEVER attempt to power a device requiring more amperage than
generator or receptacle can supply.
• DO NOT overload the generator. See Don't Overload Generator.
120 Volt AC, 20 Amp, Duplex Receptacles
The duplex receptacles are protected against overload by
push-to-reset circuit breakers.
Use receptacle to operate 120 Volt AC, single–phase, 60 Hz
electrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current. Use cord sets that are rated for 125 Volt
NEMA L5-30
AC loads at 20 Amps (or greater).
Neutral
5 Volt DC USB Port
The maximum current available for the USB port is 1 Amp at
120V
5 Volts. The USB port allows you to recharge most USB
Hot
powered devices with a USB charging cable (not included).
NOTICE For charging ITE (Information Technology
Equipment) only.
12 Volt DC Receptacle
Ground (Green)
The maximum current available for the battery charge circuit
is 5 Amps. A DC circuit breaker protects this receptacle from
overloads. If an overload occurs, the circuit breaker will trip
(push button pops out). Wait a few minutes and push the
button in to reset the circuit breaker.
This receptacle allows you to recharge a 12 Volt automotive
or utility style storage battery with the battery charge cable
provided.
This receptacle can not be used to crank an engine having a
discharged battery. See Charging a Battery before attempting
to recharge a battery.
NOTICE When using the battery charge circuit and USB
port, turn the POWERSMART switch to the OFF (0) position
for best performance.