Technical Data (Data Sheets 1; Dimensions, Mechanics, Number Of Inputs/Outputs - IFM Electronic ecomat 100 R 360 Notice De Montage Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

S
C
CR7505
AFETY
ONTROLLER
CR7505
Mobile controller
SafetyController
SK3 to EN 954-1
CANopen safety
2nd CAN interface
Programming
according to IEC 61131-3
10...32 V DC
Technical data
Housing
Dimensions (H x W x D)
Mounting
Connection
Weight
Housing/storage temperature
Protection
Input/output channels
total
Inputs
possible configurations
Outputs
possible configurations
Abbreviations
= safety-related
--
= not safety-related
A
= analogue
B
= binary High Side
H
B
= binary Low Side
L
FRQ/CYL = frequency inputs
I
= pulse High Side
H
I
= pulse Low Side
L
PWM
= pulse width modulation
PWM
= current-controlled output
I
%IW...
= IEC address for analogue input
%IX...
= IEC address for binary input
%QX...
= IEC address for binary output
ifm electronic gmbh • Teichstraße 4 • 45 127 Essen
28
PAGE
43
5,5
LED
Controller as black box system
for the implementation of a central or decentralised system design
closed, screened metal housing with flange fastening
screw connection by means of 4 M5xL screws according to DIN 7500 or DIN 7984
mounting position horizontal or vertical to the mounting wall
55-pin connector, latched, protected against reverse polarity, type AMP or Framatome
AMP junior timer contacts, crimp connection 0.5/2.5 mm²
– 40...75 °C (depending on the load) / – 40...85 °C
IP 67 (for inserted plug with individually sealed cores e.g. EC2084)
max. 24 (the total number which is available depends
on the wiring and configuration of the controller)
Number Signal
Version
8
digital
for positive sensor signals
analogue
0...10/32 V DC, 0/4...20 mA or ratiometric
or
4
digital
for positive sensor signals
4
digital
for positive sensor signals
frequency
max. 50 kHz
or
4
digital
for positive sensor signals
frequency
max. 1 kHz
or
Number Signal
Version
4
digital
positive switching (High Side), diagnostic capability
PWM
PWM frequency 20...250 Hz
or
current control
0.1...4 A
or
4
digital
positive switching (High Side), diagnostic capability
PWM
PWM frequency 20...250 Hz
or
current control
0.1...4 A
or
We reserve the right to make technical alterations without prior notice.
±1
226
±1
200,5
153 x 226 x 43 mm
1.2 kg
max. 20 (corr. to 4 outputs)
max. 8 (corr. to 16 inputs)
15
B
--
L
A
B
--
L
B
L
I
L
B
L
I
L
B
H
--
PWM
PWM
I
B
H
PWM
PWM
I
CR7505 / page 1
16.10.2006

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cr7505

Table des Matières