Technical Data - Victron energy EasySolar 12/1600/70-16 MPPT 100/50 Manuel

Associe un contrôleur de charge solaire mppt, un chargeur/convertisseur et une distribution ca dans un seul boîtier
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

11. TECHNICAL DATA

EasySolar
PowerControl / PowerAssist
Transfer switch
INVERTER
Input voltage range
'Heavy duty' output AC 0
Output AC1, 2, 3
Cont. output power at 25 °C (3)
Cont. output power at 40 °C
Peak power
Maximum efficiency
Zero-load power
Zero load power in search mode
CHARGER
AC Input
Charge voltage 'absorption'
Charge voltage 'float'
Storage mode
Charge current house battery (4)
Battery temperature sensor
Programmable relay (5)
Protection (2)
Maximum battery current
Maximum PV power,
Maximum PV open circuit voltage
Maximum efficiency
Self-consumption
Charge voltage 'absorption', default
setting
Charge voltage 'float', default setting
Charge algorithm
Temperature compensation
Protection
28
EasySolar 12/1600/70
Inverter/charger
Solar Charge Controller
6a,b)
16 A
9,5 – 17 V
16 A
Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
1600 VA / 1300 W
1200 W
3000 W
92%
8 W
2 W
Input voltage range: 187-265 VAC
Input frequency: 45 – 65 Hz
14,4 / 28,8 V
13,8 / 27,6 V
13,2 / 26,4 V
70 A
a - g
50 A
700 W
100 V
98 %
10 mA
14,4 V
13,8 V
multi-stage adaptive
-16 mV / °C resp. -32 mV / °C
a - g
EasySolar 24/1600/40
Yes
19 – 33 V
94%
10 W
3 W
Power factor: 1
40 A
yes
yes
1400 W
100 V
28,8 V
27,6 V

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Easysolar 24/1600/40-16 mppt 100/50Of1-67-008930Of1-67-008925

Table des Matières