ControLs
Button
Function
a
Hood Functions On/Off
B
Manages motor speed:
0--v1--v2--v3--v4--B
C
Manages Lighting Intensity:
0--L1--L2--L3--LMax
Enables / Disables the Remote
Control Receiver.
D
Filter ResetResets the Filter
saturation alarm when the
button is touched with the
motor and lights turned off.
Enables/Disables the Acti-
vated Charcoal Filter Alarm.
When the Hood is switched off, none of the functions is displayed, and only the normal lettering on the control
panel is visible. all the rest will light up (intensity 50%) when button a is touched. The commands are activated
by touching the selected function, which lights up more brightly (intensity 100%) than the other hood functions
(intensity 50%). When no commands are given for at least 10 seconds, only the selected functions will be lighted
(intensity 100%) and all the rest will turn off (intensity 50%). it is possible to activate one of the hood functions
(Speed and Lighting) not just by touching the control panel, but also by placing a finger on the panel and sliding
it towards the chosen function without lifting it off. if the motor and lights are turned off, by setting them to zero, all
the command LeDs will remain on at 50%, and if no further commands are given in the next 10 seconds, then all
the LeDs will be turned off with the exception of the "0" LeDs, which will remain on for a further 15 minutes.
LiGHtinG
Warning: This appliance is fitted with a
white LeD lamp classed as 1m according
to En 60825-1: 1994 + A1:2002 + A2:2001
standards; maximum optical power emitted
@439nm: 7µW. Do not look directly at the light
through optical devices (binoculars, magnifying
glasses...).
• For replacement contact technical support.
("To purchase contact technical support").
a
B
Specifications
When the button is touched with the hood turned off, all functions
light up (intensity 50%) and are enabled.When the button is touched
with the hood in operation, all functions are turned off and disabled
(Motor off + Lights off).
When the area is touched, the motor starts at the speed required.b = inten-
sive speed, timed to run for 10 minutes, after which the system will return
to the speed set before.When the required speed is touched, it will become
brighter (intensity 100%) than the other functions (intensity 50%).
When this area is touched, the Lights turn on at the required intensity.
When the lighting intensity is touched, it will become brighter (intensity
100%) than the other functions (intensity 50%).
When this button is pressed and held for 4 seconds (motor off +
Lights off), in the absence of other alarms, the Led will flash for:
4 seconds to indicate that the Remote control has been activated
2 seconds to indicate that the Remote control has been Deactivated
after 100 hours operation the Led lights up continuously to indicate
saturation of the Metal Grease Filters.After 200 hours operation the
Led flashes to indicate saturation of the activated charcoal Filters.
When this button is pressed and held for 4 seconds (motor off +
Lights off), in the absence of other alarms, the Led will flash for:4
seconds to indicate that the activated charcoal Filter alarm has been
activated2 seconds to indicate that the activated charcoal Filter alarm
has been deactivated