PERFORMANCE DATA SHEET
Linuron
Estrone
Nonylphenol
Meprobamate
Carbamazepine
DEET
Metolachlor
TCEP
TCPP
Phenytoin
Ibuprofen
Naproxen
Bisphenol A
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).
Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/incidental contaminants are those
compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/
perception of drinking water quality.
For installation, operation, and maintenance instructions please refer to the
Owners Manual.
It is important that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised. Property
damage can occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter part #EDR3RXD1/EDR3RXD1B.
The filter monitor system measures the amount of water that passes through
the filter and alerts you when it is time to replace the filter. To learn how to
check the water filter status, see "Using the Controls" or "Water Filtration
System" in the User Instructions or User Guide.
After changing the water filter, flush the water system. See "Water and Ice
Dispensers" or "Water Dispenser" in the User Instructions or User Guide.
These contaminants are not necessarily in your water supply. While testing was
performed under standard laboratory conditions, actual performance may vary.
For installation, operation and maintenance instructions please refer Owner's
Manual.
The product is for cold water use only.
The water system must be installed in compliance with state and local laws and
regulations.
*Class I particle size: >0.5 to <1 um
Based on the use of Cryptosporidium parvum oocysts
††
Fibres greater tha 10 um in length
NSF is a registered trademark of NSF International.
®
28 | ASSISTANCE
140 ± 20%
140 ± 20%
1400 ± 20%
400 ng/L ± 20%
1400 ng/L ± 20%
1400 ng/L ± 20%
1400 ng/L ± 20%
5000 ng/L ± 20%
5000 ng/L ± 20%
200 ng/L ± 20%
400 ng/L ± 20%
140 ng/L ± 20%
2000 ng/L ± 20%
20 ng/L
20 ng/L
200 ng/L
60 ng/L
200 ng/L
200 ng/L
200 ng/L
700 ng/L
700 ng/L
30 ng/L
60 ng/L
20 ng/L
300 ng/L
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certified for
cyst reduction may be used on disinfected waters that may contain filterable
cysts. EPA Est. No. 082047-TWN-001.
Refer to the "Warranty" section (in the User Instructions or User Guide) for the
Manufacturer's limited warranty, name and telephone number.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Your water filtration system will withstand up to 120 pounds per square inch
(psi) water pressure. If your water supply is higher than 80 psi, install a pressure
reducing valve before installing the water filtration system.
96.3%
90.6%
93.7%
94.9%
98.6%
98.6%
98.6%
98.1%
98.2%
94.5%
95.6%
96.9%
99.1%
Potable City or Well
30 psi - 120 psi (207 kPa - 827 kPa)
33°F - 100°F (0.6°C - 37.8°C)
0.5 gpm (1.89 Lpm) @ 60 psi (413.7 kPa)