Fault
LEDs on bat‐
tery and beeps
on the sprayer
cession for 15
seconds.
The pump cuts
3 LEDs emit
out during opera‐
red light.
tion.
The sprayer run‐
time is too short.
Sprayer does not
pick up plant pro‐
tection product.
The spraying unit
vibrates and the
pressure gauge
oscillates.
The spray jet has
changed shape.
The plant protec‐
tion product
emerges from
the sprayer in the
area of the hose
clamp.
Cover cannot be
opened.
36
Cause
No electrical contact
between sprayer and
battery.
Sprayer or battery are
damp.
The sprayer is too
warm.
There is an electrical
fault.
The battery is not fully
charged.
The battery service
life has been excee‐
ded.
The pump is stuck.
The filter or the
spraying unit are clog‐
ged.
The pulsation damper
on the pump is not
working properly.
The nozzle is blocked. ► Clean the nozzle.
The nozzle is worn.
The hose clamp has
come loose.
The pressure in the
container is too high.
Remedy
► If 4 LEDs continue to flash red and short
beeps sound in quick succession: Do not
use the battery and contact your STIHL
dealer for assistance.
► Remove the battery.
► Clean electrical contacts in the battery
compartment.
► Insert battery.
► Allow sprayer or battery to dry.
► Remove the battery.
► Allow sprayer to cool down.
► Remove battery and reinsert it.
► Switch on the sprayer.
► Fully charge battery as described in the
User Manual for chargers STIHL AL 101,
300, 500.
► Replace battery.
► FIll the container.
► Insert the battery and switch the sprayer
on.
► Keep the switch lever of the spray gun
pressed for approx. 1 minute.
► If there is still no plant protection product
being drawn up, do not use the sprayer
and contact your STIHL dealer for assis‐
tance.
► Clean filter and spray attachment.
► Switch off the sprayer and remove the
battery.
► Empty container.
► Insert the battery and switch the sprayer
on.
► Keep the switch lever of the spray gun
pressed for at least 30 seconds.
► Fill container again.
► Fit a new nozzle.
► Tighten the screw of the hose clamp
firmly.
► Switch off the sprayer and remove the
battery.
► Press the switch lever of the spray gun to
release the pressure.
18 Troubleshooting
0458-600-9621-C

Publicité