Les langues disponibles

Les langues disponibles

ERRORE NR
DESCRIPTION
E 8102
Error during data writing
E 8105
Error during data reading
E 8109
Discontinued data connection
E 8201
Missing SD board
E 8202
Unformatted SD board
E 8203
Error during data reading from file
E 8209
Missing synergic chart
E 9001
Antisticking
Report appearing while the machine
output is on short-circuit, in MMA or
TIG mode
E 9002
Overheating inverter
Report appearing when the har-
dware heat protection of inverter
group set in
Network error
E 9003
Report appearing when the supply
voltage exceed the specific limits or
when one or more supply phases are
missing (only 3ph machines)
E 9004
Thermal overload
Report appearing when the machine
passes the declared duty cycle
SOLUTION
TURN OFF AND TURN ON THE MACHINE
If the error remains please contact service assistance
Check board's presence
Contact service assistance
Corrupt SD board. Ask for updated files
Contact service assistance
Remove short-circuit from machine's output
Wait for machine's cooling
Check supply tension and/or the electrical phases for
3ph machines
Wait for machine operation restore
PROC.