Advanced Functions Programming (D1= "A")
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
A flashing. Press ENTER to confirm. D2 flashes.
D1
D2
Parameter
Flashing light
a
0
Garage light time
1
Door speed
2
Slowdown speed
3
Slowdown distance
4
5
Maximum thrust
6
maximum thrust in opening
maximum thrust in closing
Closing photocell used during
7
standby (in automatic mode
only)
Pushbutton operation during
8
standby (in automatic mode
only)
Opening mode
9
until D1 shows the letter
V
D3
D4
0
1
0
2
0...5.
0...9
0
1...5
0
1...5
0
0...5
1...9
X
X
1...9
0
1
0
2
0
3
0
1
0
2
0
3
0
1
0
2
0
3
STARTING UP AND PROGRAMMING
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
5 Press ESC to return to the previous display.
Pre-
determined
Options or values
option
x
No pre-warning
With pre-warning
= 3 secs;
03
03
= 2 min. 50 sec., etc
2.5
: minimum speed;
03
01
: minimum speed;
02
01
: minimum distance;
00
00
distance
Disabled
: minimum thrust (in opening);
6X
1X
: maximum thrust (in opening)
9X
: minimum thrust (in closing);
X6
X1
: maximum thrust (in closing)
X9
Immediate close
x
Restart standby time
Has no effect
Immediate close
x
Restart standby time
Has no effect
x
Opening in accordance with the mode
selected in the main functions (F)
Collective opening
(the control board does not obey the key
commands during opening)
Step-by-step opening
(the door halts if a key device is activated
during opening. The door closes when
operated again)
until the required D2
V
until the required D3 and
V
= 59 secs;
59
: maximum speed
05
: maximum speed
05
: maximum
05
VIVO-D102 Control board