Technical data
Technical data
GENERATOR
*Three-phase generation Stand-by
**Three-phase generation PRP
*Single-phase generation Stand-by
**Single-phase generation PRP
*Single-phase generation Stand-by
**Single-phase generation PRP
Power factor (Cos ϕ)
Frequency
ALTERNATOR
Type
Insulating class
ENGINE
Mark / Model
Type / Cooling system
Net power Stand-by
Net power PRP
Speed
Cylinders / Displacement
Fuel consumption (75% of PRP)
Engine oil capacity
GENERAL SPECIFICATIONS
Tank capacity
Running time (75% of PRP)
Grade of protection IP
*Dimensions / max. Lxwxh (mm)
Weight
Measured acoustic power LwA (LpA pression)
Guaranteed acoustic power LwA (LpA pression)
* Dimensions and weight are inclusive of all parts without wheels and towbar.
Declared power according to ISO 8528-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
(*Stand-by) = maximum available power for use at variable loads for a yearly number of hours limited at 500 h. No overload is
admitted.
(**Prime power P.R.P.) = maximum available power for use at variable loads for a yearly illimited number of hours. The average
power to be taken during a period of 24 h must not be over 80% of the P.R.P.
It's admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specific precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
(L
Acoustic Noise Level
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(L
)
of 95 dB(A)
WA
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A)
PLEASE NOTE: the symbol
according to 2000/14/CE directive.
GE 7000 BS/GS
6.7 kVA (6 kW) / 230 V / 29.1 A
5.5 kVA (5 kW) / 230 V / 23.9 A
6.7 kVA (6 kW) / 115 V / 58.2 A
5.5 kVA (5 kW) / 115 V / 47.8 A
0.9
50 Hz
Self-excited, self-regulated, brushless
single-phase, synchronous
H
81 kg
ACOUSTIC POWER LEVEL
)
- Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not
WA
when with acoustic noise values, indicates that the device respects noise emission limits
2000 / 14 / CE
Honda GX 390
Gasoline 4-Stroke / air
8.2 kW (11.1 HP)
6.4 kW (8.7 Hp)
3000 rpm
1 / 389 cm
3
2.4 l/h
1.1 l
6.5 l
3 h
IP 23
910x525x613
97 dB(A) (72 dB(A) @ 7 m)
97 dB(A) (72 dB(A) @ 7 m)
2000 / 14 / CE
OUTPUT
Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
GE 7000 - 7500 BS/GS
GE 7500 BS/GS
7.5 kVA (6 kW) / 400 V / 10.8 A
6.5 kVA (5.2 kW) / 400 V / 9.4 A
4 kVA / 230 V / 17,4 A
-
-
-
0.8
50 Hz
Self-excited, self-regulated
three-phase, synchronous
H
91 kg
M
1.5
REV.2-02/12