Adjustable feet. Place the drier upright so that it rests fi rmly on all four feet.
Level the drier by adjusting the feet as follows:
Lift the drier slightly.
Adjust the feet to the correct height (fi g. 3).
Lower the drier.
NB. A badly levelled appliance may cause damage to the bearings and lead to
their premature wear. This drier does not need to be anchored to the fl oor.
Make sure that the voltage indicated on the identifi cation plate attached to the
back of the appliance corresponds to that of the mains supply.
All cut-outs, electric wiring and mains sockets must have a rating such that enables
them to support the maximum load indicated on the identifi cation plate.
Once the appliance has been installed, it must be connected to the mains supply
through a single-pole switch.
The mains supply to which the appliance is connected must be fi tted with an
earthing system. If this is not the case, the manufacturer will not be held liable for
any incidents that may occur (fi g. 4).
If the power supply cable is damaged in any way, contact the appropriate
specialised customer technical service centre.
The drier must not be connected to the mains supply using indirect methods such
as extension leads or multiple adapters.
Position the appliance so that the power supply cable is easily accessible for
disconnection when the need arises.
Important: On completion of the drying cycle, disconnect the appliance from the mains supply
to prevent young children from operating the drier.
CONNECTING THE CONDENSATION DRAIN TO THE DRAINAGE SYSTEM.
The condensation can be collected in the reservoir (fi g. 10) or, alternatively, the hose
can be connected directly to the drainage system.
In this case, the collected water is pumped out.
To connect the condensation hose directly to the drainage system, proceed as
follows:
Before starting any operations, unplug the appliance from the mains socket.
Extract the hose on the back of the appliance by pulling it from its housing, (fi g.
5/6) and insert it in the waste water pipe.
GB
INSTALLING THE APPLIANCE
LEVELLING THE DRIER
CONNECTING TO THE MAINS SUPPLY
3
4
5
6