Numatic TGB 6055/100 Notice Originale page 31

Table des Matières

Publicité

Brush
Motor
300 W
Protection
Run Time
Class
IPX4
2.25 hrs MAX
Traction Drive
Net Weight 6055T Model
Motor
250W
80 Ah - 163.5 Kg,100 Ah - 172.5 Kg
Brush
Scrub Pressure
Speed
Standard
100
24 Kg
Rpm
PROBLEM
Machine will not operate
Vacuum will not operate
Poor water pick-up
No brush / scrub function
Little or no water flow
Machine just 'stops' during
operating
Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or
Model - TGB 6055/100 & 6055/100T
Vac
Brush
Motor
Sizes
400 W
550 mm
Water
Capacity
60 L
Scrub
Dimensions
Pressure Heavy
Width
32 Kg
Length
Height
CAUSE
Missing or blown fuses
Low battery charge
Machine is connected and charging
Waste tank full switch stuck or clogged
Key is off or missing
handle safety fuse blown
Missing or blown fuse
Vacuum switch not engaged
Waste water tank full
Waste water tank full
Clogged / blocked vacuum hose
Loose hose connections
Debris basket filter clogged / blocked
Separator filter clogged / blocked
Poor separator seal
Damaged separator seal
Damaged / split vacuum hose
Damaged floor tool blades
Low battery charge
Floor tool incorrectly adjusted
No brushes fitted
Brush deck raised
Lever not pressed
Missing or blown fuses
Clean water tank empty
Clean water tank filter blocked / clogged
Water flow not on
Brush deck raised
Tap not opened
Solenoid blocked
Too much load on the brush system
Brush motor fuse blown due to high load
Handle safety fuse blown
Numatic Technical helpline +44 (0)1460 269268
Pad
sizes
508 mm
Fluid
Noise
Flow
0 - 2 L/Min
71.4
dB(A)± 3dB(A)
Gross Weight (Full) 6055T Model
80 Ah - 223.5 Kg, 100 Ah - 232.5 Kg
Hand Arm
Vibration
= 560 mm
6055-0.44 m/s
= 1425 mm
6055T-0.57 m/ s
= 1120 mm
Specifications
Net
Weight
Weight (Full)
80 Ah - 156 Kg
80 Ah - 216 Kg
100 Ah - 165 Kg
100 Ah - 225 Kg
Maximum Climbing
Gradient
Scrubbing 2 %
Maximum Climbing
Gradient 6055T Model
Scrubbing 9 %
Re-charge
Charger
Time
2
8 hrs
10 Amp
2
Trouble Shooting
SOLUTION
Fit or replace fuse (page 5)
Charge batteries (page 13 / 14)
Take off charge (page 13)
Inspect & clean switch inside tank (page 11)
Insert key & turn to operating position
Replace fuse (or contact service engineer)
Fit or replace fuse (page 5)
Press switch
Empty waste water tank (page 11)
Empty waste water tank (page 11)
Remove and clean (page 11)
Push tight connections (page 7)
Remove and clean (page 11)
Remove and clean (Page 11)
Clean and refit (page 11)
Renew (contact service dept)
Renew (contact service dept)
Renew (contact service dept)
Re-charge batteries (page 13 / 14)
Adjust floor tool
Check and fit (page 6)
Lower brush deck (page 9)
Press lever
Fit or replace fuse (page 5)
Fill clean water tank (page 7)
Remove and clean (11)
Switch on water flow (Page 9)
Lower brush deck (page 9)
Open tap to desired flow
Clean solenoid seal
Decrease the brush load to best suit the
floor type (page 10).
Replace fuse & reduce load (page 5)
Replace fuse (or contact service engineer)
T 01460 68600
Gross
Drive
Speed
6055T
0-4Kph
31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tgb 6055/100t

Table des Matières