USE
• Switch off the timer function by pressing a random button (except
the one for lighting).
The cooker hood can be used in extraction mode or recirculation
mode. The air extraction capacity is adapted to the selected mode. The
hood will start up in the default extraction mode. Is has to be reset for
recirculation mode.
With an RMS kit (recirculation modification set) the air will first be
cleaned by the grease filters and then odours will be filtered by the
charcoal filter. The cleaned air is recirculated back into the kitchen.
Switching on recirculation mode
• Simultaneously press and hold the timer button and the light button
until the filter indicator flashes 3 times.
The carbon filter indicator is activated.
Switching off recirculation mode
• Simultaneously press and hold the timer button and the light button
until the filter indicator lights up for 3 seconds and then turns off.
Clean Air function
The Clean Air function allows you to freshen the air in your kitchen for a
maximum of 24 hours at level 1.
• Switch off the cooker hood.
• Press and hold the timer button for approximately 3 seconds.
The cooker hood will switch on automatically for 10 minutes every
hour at the lowest speed setting. During extraction the display
will show a fast moving 'snake'. When the hood switches off after
10 minutes, the display will show a slow moving 'snake' until the
hood switches on again after 50 minutes.
• Switch off the Clean Air function in the meantime by pressing a
random button (any button other than the light button).