ROBLIN Aqua 1200 Inox Manuel D'utilisation page 45

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
aide au diagnostic - Diagnostic aid - Hilfe bei der Diagnose - Aiuto alla diagnostica - ayuda a la diagnosis - Diagnosetabel
Please observe the recommendations previously cited in the MAINTENANCE and WARRANTY AND AFTER-SALES SERVICE PARA-
GRAPHS.
Problems
The hood does not work.
The hood does not
answer to the remote
control.
Noise, vibration or
suction problem.
GB
Faulty lighting.
44
Details and/or
conditions of the
problems
1.
Check the general electrical distribution board.
No function operates
2.
Check the connection of the power cable to the
(suction, lighting, etc.).
hood and its connection to the domestic electricity
mains.
1.
Check that the batteries are correctly positioned
in the remote control unit.
2.
Check the state of charge of the remote control
batteries.
3.
The distance between the hood and the remote
control is too long or the direction (angle) of the
remote control in relation to the hood is not good.
4.
The receiver is off.
1.
Check the condition of your filters (anti-odour).
2.
Check the positioning and fitting of the anti-odour
filter.
Recirculation version.
3.
Check the condition of your anti-grease filters.
1.
Check the condition of your anti-grease filters.
External ventilating
2.
Check the installation of the hood, (fume hood and
version, low suction
outlet duct, valve, pipe length, number of elbows
despite satisfactory
and pipe diameter).
motor speed.
Check the condition of the light sources.
Step 1
Checking operations
Step 2
Action to be taken if «Step 1» has not helped to
solve the problem or if it requires an additional
maintenance operation.
If you observe a fault in the electricity power
supply (1 or 2) call in an electrician.
If everything is OK but the problem persists, call
in a specialized repairer
5.
Reposition the batteries.
6.
Change the batteries (2LR03 1.5 volts) in the
remote control
7.
Change the position of the remote control.
8.
Check the remote control.
If everything is OK but the problem persists, call
in a specialized repairer.
4.
Clean or change the anti-odour filters.
5.
Replace the anti-odour filters.
6.
Clean your anti-grease filters.
If everything is OK but the problem persists, call
in a specialized repairer.
3.
Clean your anti-grease filters.
If you observe faulty installation or fitting: call in
your dealer / installer
If everything is OK but the problem persists, call
in a specialized repairer.
Change faulty bulbs.
For LEDS call in a specialized repairer.