Switching on and off

• Check connecting line and plug on damages first.
• Push button MAGNET ON, in order to initiate the magnet and the magnetic adhesion is guaranteed.
For better positioning loosen the clamping lever (H). Now the drill base can be pivoted 30° to the left or to
the right, respectively it can be slid 10 mm forwards or backwards.
• For non-magnetizable materials, please use the ROTABEST Vacubest (Prod.-No. 18150).
• When working on walls and ceilings secure machine with safety belt.
For these operations we recommend cooling with our spray ALFRA BIO 2000, Prod.- No. 21010.
• Push the button MOTOR ON to start the motor.
• In case of a damaged magnet foot the motor won´t start.
• To switch off the machine proceed in reverse order, first MOTOR OFF, then MAGNET OFF.
MPI-System
• At function „magnet on", 100% of the mangnet power is available right from the beginning.
• Simultaneously a timing relay will be activated which is preset to 60 seconds. If the motor will not be
switched on after "magnet on" the LED of the magnet switch on the key pad is flashing and a buzzer
sounds at the same time. This time-controlled alarm will be also activated after drilling is done and the
motor is switched off but the magnet is still on.
• A functional check of the LED and of the buzzer is carried out if the machine will be connected to the
mains with the electric cable (short flashing of the LED and short buzzing). With it it it's possible to test
the model in use respectively the control in use fast and easily on site.
• The new PCBs are 100% compatible with machines of older type series, i.e. in case of repair they can be
replaced respectively exchanged without problems.