Roller shutter selection
With the roller shutter function, the roller shutter runs in maintained operation
mode after a travel button is pressed.
Venetian blind selection
With the venetian blind function, the venetian blind runs in touch mode to facil-
itate precise positioning of the laths. If you press a travel button for longer than
1 second, the venetian blind runs in maintained operation mode.
After moving to the programmed intermediate and end positions, the laths
automatically tilt (if the tilt position was programmed).
Manual/Automatic slide switch
In slide switch position , only manual drive commands can be performed
(e.g. UP, STOP, DOWN via button actuation).
In slide switch position
time, Astro function, etc.).
The current setting is shown on the display.
Channel
The channel of a transmitter can be programmed into one or more receivers.
One receiver is operated through an individual command, several receivers
through a group command.
Central command
If all the channels of the transmitter are selected, it is possible to operate all of
the assigned receivers/groups simultaneously.
Channel selection button
Up to 5 channels can be selected using the channel selection button. The indi-
vidual channels are indicated by the corresponding channel indicator lamp
lighting up. If all of the channel indicator lamps light up simultaneously, the
central command can be programmed or transmitted.
You can make a note of the programmed channel in the la-
belling field underneath the transparent film.
36 - en

Explanation of functions

, automatic drive commands can be performed (e.g.