SIMUDRIVE SD100Hz
11 DIAGNOSTIC AND TROUBLESHOOTING
11.1 Indicator light status
Off
Permanently lit
11.2 Diagnostic
POWER indicator
Electronic in motor setting mode
→ If necessary, check the direction of rotation of the motor and adjust the motor end limits.
Product adjusted
Motor thermal cut-out
→ Switch the power supply off, wait about 5 min. then switch the power supply back on.
Photoelectric cells indicator light
Normal operation
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check the alignment and wiring of the cells.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door
to be controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Safety edge indicator light
• Normal operation
• If the safety edge is not activated when the door encounters an obstacle when closing,
the direction of rotation of the motor must be checked.
• Detection in progress
→ Once detection is complete, the indicator light goes out.
• Permanent fault
→ Check the safety edge wiring.
NOTICE! After 3 mins, the wired control input (terminals 20 and 21) allows the door
to be controlled in dead-man mode.
Auto-test in progress
→ Once the auto-test is complete, the indicator light goes out.
Fall protection indicator light
Normal operation
Slow flashing
Rapid flashing
Very rapid flashing
EN
39