Information Screens - Cembre B1350-C Notice D'utilisation Et Entretien

Masquer les pouces Voir aussi pour B1350-C:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4. DISPLAY
The OLED display switches on automatically when the operating or pressure release buttons are
pressed, and off after 60 seconds of non-operation.
The display shows:
The main operational parameters of the tool processed by the circuit board, such as peak pressure
or force reached.
Information on the condition of the tool, such as the charge level, the battery temperature and
maintenance requirements.
Any operational or procedural ERRORS.
Use the touch button (8) to navigate through the menu screens to manage INFORMATION AND
SELECTION:

4.1) INFORMATION SCREENS:

time the tool is started and during the entire work cycle.
F
= 125.2 kN
m
Fp = 94.5 kN
F
= 14.07 ton
m
Fp = 10.61 ton
P
= 692 bar
m
Pp = 522.3 bar
P
= 10037 psi
m
Pp = 7575 psi
BATTERY
1000
-29000
B1350
13AB485
display a pre determined parameter which will then appear each
Fm: Minimum set force, expressed in kN.
Fp: Peak force reached, expressed in kN.
(screen as factory setting)
Fm: Minimum set force, expressed in USA sh. tons.
Fp: Peak force reached, expressed in USA sh. tons.
Pm: Minimum set pressure, expressed in bar.
Pp: Peak pressure reached, expressed in bar.
Pm: Minimum set pressure, expressed in psi.
Pp: Peak pressure reached, expressed in in psi.
Battery charge level.
No. of cycles performed.
No. of cycles before scheduled recommended maintenance.
Cembre logo, tool model.
tool serial no.
F
= 125.2 kN
m
F
= 102.3 kN
p
P
= 692 bar
m
P
= 565 bar
p
max.
BATTERY
LED
ON
LED
OFF
F
= 125.2 kN
m
OK
P
= 692 bar
m
OK
min.
BATTERY
10
3 SEC.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

B1350-caB1350-ceB1350-ct

Table des Matières