Heater model
HPCS6U1HB
HPCS7U1HB
HPCS8U1HB
HPCS9U1HB
Table 3. Supply wires
1.
4x
4.
Figure 7.
Installing the wall-mounting device (1.) and the heater (2.–4.)
3.7. Resetting the Overheat Protector
If the temperature of the sauna room becomes
dangerously high, the overheat protector will
permanently cut off the supply of the heater. The
overheating protector can be reset after the heater
has cooled down. See figure 8. Please check that
the stones are piled properly.
Input
Voltage
Ph
kW
6,0
240
1
6,8
240
1
8,0
240
1
9,0
240
1
6x
6x
EN
Amperage
1-Group
2-Group
connection
connection
25
16,7
28,25
18,9
33,4
22,3
37,5
25
2.
A. Connection box
B. Connection cable
A
B
Installation example
Parts not supplied
Figure 8.
Reset button for overheat protector
Min. 90 °C Copper supply wire
AWG No.
1-Group
2-Group
connection
connection
12
14
10
12
8
12
8
10
3.
2x
11