3. Operation
3.3. Mode select
■ Press the operation mode (
operation mode 2.
Cooling mode
Drying mode
Fan mode
Heating mode
Automatic (cooling/heating) mode
Information for multi system air conditioner (Outdoor
unit: MXZ series)
▶ Multi system air conditioner (Outdoor unit: MXZ series) can
▶
connect two or more indoor units with one outdoor unit.
According to the capacity, two or more units can operate
simultaneously.
• When you try to operate two or more indoor units with one outdoor
unit simultaneously, one for the cooling and the other for heating, the
operation mode of the indoor unit that operates earlier is selected. The
other indoor units that will start the operation later cannot operate,
indicating an operation state in flashing.
In this case, please set all the indoor units to the same operation
mode.
• There might be a case that the indoor unit, which is operating in
(AUTO) mode. Cannot change over to the operating mode (COOL ↔
HEAT) and becomes a state of standby.
• When indoor unit starts the operation while the defrosting of outdoor
unit is being done, it takes a few minutes (max. about 15 minutes) to
blow out the warm air.
• In the heating operation, though indoor unit that does not operate may
get warm or the sound of refrigerant flowing may be heard, they are
not malfunction. The reason is that the refrigerant continuously flows
into it.
Automatic operation
■ According to a set temperature, cooling operation starts if the room
temperature is too hot and heating operation starts if the room
temperature is too cold.
■ During automatic operation, if the room temperature changes and
remains 2 °C or more above the set temperature for 15 minutes, the
air conditioner switches to cooling mode. In the same way, if the room
temperature remains 2 °C or more below the set temperature for 15
minutes, the air conditioner switches to heating mode.
Cooling mode
15 minutes (switches
from heating to cooling)
15 minutes (switches
from cooling to heating )
■ Because the room temperature is automatically adjusted in order to
maintain a fixed effective temperature, cooling operation is performed
a few degrees warmer and heating operation is performed a few
degrees cooler than the set room temperature once the temperature
is reached (automatic energy-saving operation).
3.4. Temperature setting
▶ To decrease the room temperature:
▶
Press
button ③ to set the desired temperature.
The selected temperature is displayed 3.
▶ To increase the room temperature:
▶
Press
button ③ to set the desired temperature.
The selected temperature is displayed 3.
) button ② and select the
Set temperature +2°C
Set temperature
Set temperature -2°C
• Available temperature ranges are as follows:
Cooling/Drying:
19 - 30 °C
Heating:
17 - 28 °C
Automatic:
19 - 28 °C
• The display flashes either 8 °C - 39 °C to inform you if the room
temperature is lower or higher than the displayed temperature.
3.5. Fan speed setting
■ Press the Fan Speed button ① as many times as necessary while the
system is running.
• Each press changes the force. The currently selected speed is shown
at Ⓐ.
• The change sequence, and the available settings, are as follows.
ON/OFF
①
MODE
CHECK
TEST RUN
① Press
FAN
button to select a desired fan speed.
• Each time you press the button, available options change with the
display Ⓐ on the remote controller, as shown next.
Remote controller display
Fan speed
(Auto)
Low
4-stage
( )
3-stage
( )
2-stage
( )
The wind speeds that can be selected depend on the model.
Note that some units do not provide an "Auto" setting.
The display and the fan speed of the unit will differ in the following
situations:
• When the unit is in STAND BY mode or in DEFROST mode.
• Just after the heating mode (while waiting to change to another
mode).
• When the temperature of the room is higher than the temperature
setting of the unit operating in the heating mode.
• In the dry operation, the indoor fan automatically turns to low-speed
operation. Switching of fan speed is impossible.
3.6. Ventillation
▶ For LOSSNAY combination
▶
3.6.1. For Wireless Remote-controller
● The ventillator will automatically operate when the indoor unit turns on.
● No indication on the wireless remote controller.
Ⓐ
TEMP
FAN
AUTO STOP
VANE
AUTO START
LOUVER
h
min
SET
RESET
CLOCK
AAA
AAA
Middle 2
Middle 1
(Middle)
High
5