0.6 - WARNINGS FOR R290 REFRIGERANT GAS

1. THE APPLIANCE CONTAINS R290 GAS (FLAMMABILITY CLASSIFICATION
A3).
2. THE APPLIANCE SHALL BE STORED IN A WELL-VENTILATED AREA
WHERE THE ROOM SIZE CORRESPONDS TO THE ROOM AREA AS SPEC-
IFIED FOR OPERATION.
3. THE APPLIANCE MUST BE INSTALLED, USED AND STORED IN A ROOM WITH A
FLOOR SURFACE HIGHER THAN THE 4m
4. THIS APPLIANCE CONTAINS A QUANTITY OF REFRIGERANT GAS R290
EQUAL TO THE ONE INDICATED IN THE DATA LABEL LOCATED ON THE
APPLIANCE.
5. THE APPLIANCE SHALL BE STORED IN A ROOM WITHOUT CONTINUOUSLY
OPERATING IGNITION SOURCES (FOR EXAMPLE: OPEN FLAMES, AN
OPERATING GAS APPLIANCE OR AN OPERATING ELECTRIC HEATER).
6. Do not pierce or burn.
7. Be aware that the refrigerants may not contain an odour.
8. R290 is a refrigerant gas in compliance with the European directives on
environment. Do not pierce any part of the refrigerant circuit.
9. Do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
10. Do not use tools different from those recommended by the manufacturer
when defrosting and cleaning the appliance.
11. If the appliance is installed, used or stored in a non-ventilated area, the room
must be designed to prevent the accumulation of refrigerant leaks with
the consequent fire or explosion hazard due to the refrigerant combustion
caused by electrical heaters, stoves or others sources of ignition.
12. Compliance with national gas regulations shall be observed.
13. Keep ventilation openings clear of obstruction.
14. The appliance shall be stored so as to prevent mechanical damage from
occurring.
15. Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certificate from an industry-accredited
assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment
specification.
16. Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other
skilled personnel shall be carried out under the supervision of the person
competent in the use of flammable refrigerants.