Télécharger Imprimer la page

Master B 5 ECA Mode D'emploi page 12

Générateur électrique d'air chaud

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
GB
IMPORTANT!!! Carefully read this service manual before
you start to use, repair or clean the heater. Improper use of the
appliance may cause serious injuries, burns, electric shock or fire.
1.
Safety instructions.
The appliance has been designed for heating closed areas such as e.g.
warehouses, shops and houses.
It complies with
the Directive
including the harmonised standards No. EN 60335-1 and EN 60335-2.
WARNING !!! Do not place the heater directly under the wall
outlet. Do not touch internal components of the heater.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not
play with the appliance.
-
Do not cover the heater when it is operating. The appliance
may get overheated.
• Do not operate the appliance close to humid places such as water
tanks, bathtubs, showers or swimming pools. Any contact with water
may be the reason of short-circuit or electric shock.
• The heater should be kept at a safe distance from flammable
materials. The minimum safety distance should not be inferior to 0.5
m, otherwise you run the risk of starting the fire.
• Do not use the heater in dusty spaces or rooms where gasoline,
solvents, paints or other volatile and inflammable materials are
stored in order to avoid the risk of explosion.
• The heater should not be used close to the curtains or other textiles
in order to avoid the risk of fire.
• Be particularly cautious when using the heater in the rooms
frequented by children or animals.
• The heater should be supplied from a source meeting the
requirements specified on the rating plate.
• Use only a feeder cable including the earth lead in order to avoid
electric shock in emergency situations.
• Do not unplug the heater by pulling the wire out of the wall socket.
• Unplug the heater when not used in order to avoid accidental
damages.
• Before you dismantle the casing check if the feeder cable has been
pulled out of the wall socket. Internal components may be live.
2.
Unpacking and transport.
• Open the package and take the heater out including all the safety
locks installed for the period of transport.
• Should the appliance seem damaged, notify immediately the seller
of the same.
• Transport the heater using the lifting eyes No. 1 shown in Figs. 1,
page 2.
• The heater should be transported in original package including the
safety locks.
3.
Description of individual components.
See Figs. 1-2 Page. 2.
PROBLEM
The motor operates while the appliance does
not heat.
The motor does not operate while the heating
elements are hot.
The whole appliance does not operate.
Reduced air flow.
No. 2006/95/EC, 2004/108/EC
10.
TROUBLESHOOTING
REASON
Thermal circuit breaker is active.
Thermostat has been damaged.
Heating element has been damaged.
Motor has been damaged.
Fan has been stopped.
Switch has been damaged.
Electric circuit open.
Switch has been damaged.
Foul air duct.
Motor has been damaged.
1) Lifting eye
2) Thermostat
3) Front protective grid
4) Heating element
5) Casing
6) Switch
7) Cable penetration.
4.
Switching on.
WARNING !!! Carefully read this service manual before you start
to use the heater. The instructions contained herein will allow you
to use the appliance in a safe manner.
Make sure the power supply cable has not been damaged. If the
supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Moreover, check if the technical parameters of power supply source
comply with the requirements specified on the rating plate.
Place the appliance in its upright position. Make sure the switch is in
its "0" position shown in Fig. 3. Connect the heater to the power
supply source. Turn the switch and leave it for 5 seconds in the
positions as follows:
• Fan only: Fig. 4;
st
• 1
degree of heating: Fig. 5, and
nd
• 2
degree of heating: Fig. 6.
5.
Switching off.
Turn the switch to its "0" position. Once the heating is off, leave the
fan operating for 3 minutes.
6.
Temperature control.
The temperature in the room may be set by means of the control knob
(Fig. 7, page 2). Once the pre-set temperature is produced, the
thermostat will automatically switch the heating elements off while
the fan will continue to operate thus protecting the appliance from
overheating. If the temperature falls down beyond the pre-set value,
the system will switch the heating elements on again.
7.
Thermal circuit breaker.
The appliance has been equipped with an integrated thermal circuit
breaker ensuring high safety level. The breaker will automatically
switch the power supply off once a limit temperature is exceeded.
Should it happen, let the appliance cool down and only then, look for
the reason of the problem. Next push the "RESET" button (Fig. 7)
with a pointed tip in order to unlock the thermal circuit breaker. If the
heater does not operate, contact the seller or approved service centre.
8.
Out-of-season storage.
Should the appliance remain idle for a long period of time, clean
it before shoving by blowing the inside with compressed air. The
heater should be kept in a dry and clean place. Before you start using
it again make sure the power supply cable has not been damaged. In
the case of any doubts contact the seller or approved service centre.
9.
Functional inspection.
The appliance should be checked at least once a year by competent
service personnel approved by the manufacturer. Any inspections or
repairs should be conducted by competent personnel only.
SOLUTION
Let the heater cool down and push the "RESET" button .
Replace the thermostat.
Replace the heating element.
Replace the motor.
Unlock / clean the fan.
Replace the switch.
Check power supply connection.
Replace the switch.
Open the air duct.
Replace the motor.
12
8) Back protective grid.
9) Power supply cable.
10) Base foot.
11) Fan.
12) Motor .
13) Plug.

Publicité